48
Operation
Recovery tank
(Fig. 21/2+5)
The waste water filter (Fig. 21/2) is lo-
cated under the recovery tank lid
(Fig. 21/5) at the top of the recovery
tank and is connected to the end of the
suction pipe. It filters large particle dirt
from the waste water and must be in-
spected or cleaned daily, refer to Sec-
tion 5.6.4.
Fresh water tank
(Fig. 21/3+6)
In order to fill fresh water and cleaning
agent, pivot up the lid of the fresh water
tank (Fig. 21/6) and lock it. The tank is
filled through the filling neck (Fig. 21/3),
refer to Section 5.5.1.
Lid lock
(Fig. 21/4)
The lock prevents the lid falling shut. To
lock the lid, move the bar and latch in
place. The lid lock functions in the same
way on the fresh water tank and recov-
ery tank.
Rear doors
(Fig. 21/7+9)
Open the rear doors to access the
draining hoses for waste water and
fresh water.
Waste water draining hose
(Fig. 21/11)
The draining hose for waste water
hooked is in the left-hand rear door.
Only drain off waste water through this
hose at an appropriate location, refer to
Section 5.6.1.
Fresh water draining hose
(Fig. 21/10)
The draining hose for fresh water hangs
to the left of the suction turbines. Only
drain off the fresh water through this
hose at an appropriate location, refer to
Section 5.5.2.
Rear panel frame
(Fig. 21/8+12)
In order, for example, to access the flap
to clean the recovery tank, the rear pan-
el frame must be opened. To do this,
pull the lock lever (Fig. 21/12) up and
open the unlocked rear panel frame
(Fig. 21/8).