background image

PRE-OPERATION CHECKS

 1.  Ensure there are no obvious signs of mechanical damage to the handrails,  

 

  

platform, lifting structure or chassis. 

2.  Check platform access gate closes when released and that the latch 
  

engages correctly.

 3.  Check castors and wheels rotate freely and are undamaged. 
 4.  Check castor wheel and castor fixings. Check circlip (red ring) is correctly located    
  

on end of stub axle and retained with hub cap (

Pic A

.)

 5.  Check emergency lowering is functioning correctly (refer to procedure on p.8).
 6.  Ensure the battery (where applicable) is fully charged, referring to the LED or dial    
  

battery condition indicator on the pendant controller (

Pic 5

).

7.  Ensure the hydraulic oil level is at the correct level. Do not overfill.
8.  Check there are no hydraulic oil leaks and that all hydraulic connections 
  

are tight.

9.  Cordon off area around machine in accordance with guidelines.

NORMAL OPERATION

Only use the machine internally,  on hard level surfaces. Ensure a person is available 
at ground level to assist in case of emergency.

Position machine under application.  Refer to working envelope    

 

diagram if necessary.
1.

 

Apply both castor brakes (

Pic 1

). 

2.  Check spirit level to ensure machine is level (

Pic 2

).

3.  Ensure the emergency lowering valve is closed (push and twist 90º,  

 

 

  

release - do not force) (

Pic 3

).

 

4.  Turn key switch in emergency stop button (located at the base of the  

 

 

  

machine), then pull to release (

Pic 4

).

5.  Battery condition indicator on pendant controller will indicate battery charge (

Pic 5

).

6.  Check there are no overhead obstructions.
7.  Enter platform via step and gate and ensure the gate is closed 
  

and latched correctly when in platform. Do not elevate if the access gate is  

 

  

not closed and latched.

8.  Press        arrowed button to elevate. Press        arrowed button to descend.
9.   In case of uncontrolled platform elevation or descent, depress  

 

 

  

red emergency stop button (

on pendant controller or at base of 

  

machine - refer to Pics 4 & 5

).

The user shall obtain the guidance and approval of the manufacturer in 
the event of any special working methods or conditions which are outside 
those specified by the manufacturer.

OPERATING PROCEDURES

7

Locked

1

Unlocked

1

2

4

3

55

 Pic. A

Never affix the pendant controller to the guardrails or 
toolbox area of the platform

Содержание 830p

Страница 1: ...www powertowers com Operating and Maintenance Manual...

Страница 2: ...he risks associated with portable scaffold towers It is suitable for any application provided it is used within its specified operating parameters If used for applications such as sand blasting weldin...

Страница 3: ...e 0 mph Manual push force on level ground 9 kg Maximum total weight Inc payload 485 kg Maximum castor point load 180 kg 1 77 kN Max wheel force 180 kg 1 77 kN Closed Dimensions Length 1 195 m Width 0...

Страница 4: ...e 200N 5 Never use in the vicinity of live conductors 6 Never try to move the machine on its castors when elevated 7 Never extend the height of the platform by using boxes steps ladders etc 8 Never mo...

Страница 5: ...PRIMARY COMPONENTS PRIMARY COMPONENT LOCATIONS 5 Control Box Entrance Gate Latch Spirit Level Swivel Castor Auto Lok Braked Wheel Emergency Stop Battery Isolator Emergency Lowering Valve...

Страница 6: ...ooses to wear a safety harness an approved fall restraint type harness should be worn Operating procedures are divided into three key areas 1 Pre operation checks What to do before operating the machi...

Страница 7: ...y Position machine under application Refer to working envelope diagram if necessary 1 Apply both castor brakes Pic 1 2 Check spirit level to ensure machine is level Pic 2 3 Ensure the emergency loweri...

Страница 8: ...ntrol failure or operator incapacity and for no other purpose To lower the platform 1 Locate emergency lowering valve at base of machine see Pic right 2 Push twist 90 degrees anti clockwise and releas...

Страница 9: ...pendant controller will indicate charge level The charge is complete when the 2 Green LEDs are illuminated if the LED indicator is fitted to the pendant controller Pic D or the pointer is fully over t...

Страница 10: ...ttery charge indicator on the pendant controller will indicate charge level The charge is complete when the 2 Green LEDs are illuminated if the LED indicator is fitted to the pendant controller Pic D...

Страница 11: ...ect and reconnect to the mains supply If flashing continues seek technical support The LEDs will illuminate in sequence and when the full LED is illuminated the charge is complete Additionally the bat...

Страница 12: ...t overfilled The level must only be checked when the machine is in the transport position The correct level in this condition is approximately 3 4 from the base of the tank as indicated by the line 3...

Страница 13: ...Check rear wheels to ensure retention circlip is securely fitted to end of stub axle and plastic cap is fitted over it MOTOR CONTACTOR SOLENOIDS When conducting the six monthly LOLER inspection check...

Страница 14: ...long with a spacer washer that enables a higher bolting torque to be applied This will improve the reliability of the fix but will not increase the strength of the castor assembly The new fixing nut a...

Страница 15: ...of the castor bracket The castor is highly rated for the application so if visible distortion is evident a significant impact will have occurred and under these conditions the castor and fixing must...

Страница 16: ...bottom of the middle section contacts the lower rest buffers and the outer section continues to close over the middle section It is essential the mast closes in this sequence To ensure the mast secti...

Страница 17: ...ructure and chassis Swivel castor condition and security Axle and wheels for condition and security Condition and operation of spirit level Condition of component and battery covers Condition of all l...

Страница 18: ...riodically not required if AGM battery is fitted If this is not practical then the charger should be switched on once a week for half an hour This is especially important in cold conditions The hydrau...

Страница 19: ...ognised agents for repair or assessment against a warranty claim on the machine or component Materials and or labour costs to renew repair or replace components due to fair wear and tear Faults arisin...

Страница 20: ...Charger 110V IP20 PT E 001 Battery Charger 110V IP65 PT E 001 2 Battery charger 230V IP65 PT E 001E E 12V 105A Lead Acid Battery PT E 002 AGM Battery PT E 002AGM F 110V Plug PT E 010 HYDRAULIC PARTS P...

Страница 21: ...w Gate PTN M 350 F Rubber Buffer PT M 126 G Cover Securing Knob PT M 107 H Tool Tray PTN M 303 I Buffer Wheel PTN M 302 J Decal Set 1 PTN M 322 Decal Set 2 Nano PTN M 310 Decal Set 2 830P PTN M 310 2...

Страница 22: ...PIN CONNECTOR PLUG OPTIONAL SOLENOID DETECTION DEVICE N O N O DOWN UP N O OPTIONAL GROUND CONTROLS OPTIONAL DEAD MAN S PLATFORM CONTROLS OPTIONAL DEAD MAN S OPTIONAL GROUND CONTROLS SUZIE CABLE POWER...

Страница 23: ...CIRCUIT DIAGRAM HYDRAULIC 23 Relief Valve preset to 65 Bar 12V DC Powerpack Single Action 2 stage lift cylinder Manual Bypass Solenoid Lock Valve Steel Pipe Orifice 3 1cc rev...

Страница 24: ...N OP UK 12 17 www powertowers com 100 British designed and manufactured...

Отзывы: