photovoltaic inverters
appendiX c - technical data
model
pVi-3.0-tl-outd
pVi-3.6-tl-outd
pVi-4.2-tl-outd
input paRameteRs
nominal dc power [kW]
3,12
3,75
4,375
max. Recommended dc power [kW]
3,5
4,15
4,82
operating input Voltage Range [V]
0,7xVstart - 580 (360 nominal)
full power mppt input voltage range (symmetrical load) [V]
160-530
120-530
140-530
full power mppt input voltage range (asymmetrical load) [V] 200-530 (@ 2kW) / 112-530 (@ 1,12kW) 190-530 (@ 3kW) / 90-530 (@ 0,75kW) 190-530 (@ 3kW) / 90-530 (@ 1,38kW)
absolute max. input Voltage [V]
600
activation voltage “Vstart” [V]
200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input)
no of independent mppt trackers
2
max. input power, each mppt [kW]
2
3
no. of dc inputs
2 ( 1 each MPPT )
3 ( 2 for MPPT1, 1 for MPPT2 )
max. dc current, each mppt [a]
10 ( 12,5 short circuit )
16 ( 20 short circuit )
dc connection
4 (2 positive, 2 negative)
6 (3 positive, 3 negative)
Weidermüller / MultiContact Ø 4mm (male - positive input + female - negative input)
Mating cable connector included
Conductor cross section: 4-6mmq/AWG12-10 - Cable Ø w/insulator: 3-6mm
input pRotection
Reverse polarity protection
Yes
fuse rating, each input (-fs suffix versions only)
NA
NA
NA
thermally protected dc side varistor
4 ( 2 for each MPPT )
pV array insulation control
according to VDE0126-1-1
dc switch (-s/-fs suffix versions only)
Integrated (Rating : 600Vdc / 25A)
output paRameteRs
nominal ac power [up to 50°c, kW]
3
3,6
4,2
max. ac power [kW]
3,3
4
4,6
ac grid connection
single phase ( Live, Neutral, PE )
nominal ac Voltage [V]
230
ac Voltage Range [V]
180-264 (may vary to comply with regulations in each country)
nominal ac frequency [hz]
50
max. ac line current [a]
14,5 ( 16 short circuit )
17,2* ( 19 short circuit )
20 ( 22 short circuit )
ac connection
Screw terminal block
Conductor cross section: Solid 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6
Cable Gland: M25 - Cable Ø: 10-17mm
line power factor
>0,995
ac current distortion [thd%]
<3,5% at rated power with sine wave voltage
output pRotection
ac side varistors
2 ( Live - Neutral / Live - PE )
ground fault protection (ac + dc leakage current)
according to VDE0126-1-1
enViRonmental paRameteRs
cooling
Natural cooling
ambient temp. Range [°c]
-25 / +60 (output power derating
above 50 °C)
-25 / +60 (output power derating
above 55 °C)
-25 / +60 (output power derating
above 50 °C)
opertaing altitude [m]
2000
acoustical noise [dBa]
< 50 @ 1mt
environmental ip Rating
IP65
Relative humidity
0-100% condensing
mechanical
dimensions [h x W x d]
547 x 325 x 210
overall dimensions (whit flanges) [h x W x d]
689 x 325 x 222
Weight [kg]
(*) Limited to 16A for UK G83/1 Version.