10.2 otheR configuRations
configuration of the Rs458 port address (address): When there are several inverters wired on the
same RS485 line (ref. Par. 7), the RS485 port address must be different for each inverter (N.B. “Auto” is not
permitted as an address); to modify the address you have to access the Address sub-menu.
date/time settings (time): On first start-up of the inverter, it is necessary to configure the date and time
by accessing the Time sub-menu.
language setting (language): If required, you can change the default language, set automatically when
“Nation” was selected, to one of the following: ENGLISH, GERMAN, FRENCH, ITALIAN, SPANISH or CZECH.
To change the language, select the Language submenu.
start-up voltage (Vstart): The start-up voltage can be regulated by accessing the Vstart sub-menu and,
in the case of independent channel configuration, it is possible to configure the Vstart for channel 1 and
channel 2 separately.
mppt scanning (mpptscan en/dis): The inverter uses the MPPT Scan to search periodically for an
absolute power peak from the relative peaks that are formed when part of the solar array is shaded.
scan interval (scan interval): The Scan Interval function determines the time interval between
consecutive MTTP scans.