background image

27

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

Trouble Shooting Chart

           

Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.

Symptom

Possible Cause(s)

Corrective Action

Pump will not run

1.   Poor electrical connection, blown fuse, tripped 
  breaker or other interruption of power; 
  improper power supply
2.   Motor or switch inoperative (go to manual 
  operation)
2a. Float movement restricted
2b. Switch will not activate pump or is defective
2c. Defective motor
3.   Insufficient liquid level

1.   Check all electrical connections for security. 
  Have electrician measure current in motor leads, 
  if current is within ± 20% of locked rotor Amps, 
  impeller is probably locked. If current is 0, 
  overload  may be tripped. Remove power, allow 
  pump to cool, then re-check current.
2a. Reposition pump or clean basin as required to 
  provide adaquate clearance for float
2b. Disconnect level control. Set ohmmeter for a 
  low rang, such as 100 ohms full scale and 
  connect to level control leads. Actuate level 
  control manually and check to see that 
  ohmmeter shows zero ohms for closed switch 
  and full scale for open switch. (Float Switch)
2c. Check winding insulation (Megger Test) and 
  winding resistance. If check is outside of range, 
  dry and re-check. If still defective, replace per 
  service instructions.
3.  Make sure liquid level is above the pump
4.  Re-check all sizing calculations to determine 
  proper pump size.
5.  Check discharge line for restrictions, including 
  ice if line passes through or into cold areas.
6.   Remove and examine check valve for proper 
  installation and freedom of operation
7.  Open valve
8.  Check impeller for freedom of operation, 
  security and condition. Clean impeller cavity 
  and inlet of any obstruction
9.  Loosen union slightly to allow trapped air to 
  escape. Verify that turn-off level of switch is set 
  so that the suction is always flooded. Clean vent
  hole
10. Check rotation. If power supply is three phase, 
  reverse any two of three power supply leads to 
  ensure proper impeller rotation
11. Repair fixtures as required to eliminate leakage
12. Check pump temperature limits and fluid 
  temperature
13. Replace portion of discharge pipe with flexible 
  connector or tighten existing piping.
14. Turn to automatic position
15. Check for leaks around basin inlet and outlets

Pump will not turn off

2a. Float movement restricted
2b. Switch will not activate pump or is defective
4.  Ecessive inflow or pump not properly sized for 
  application
9.  Pump may be air locked causing pump not to flow
14. H-O-A switch on panel is in “HAND” position

Pump hums but doesn’t run

1.  Incorrect low voltage
8.  Impeller jammed or loose on shaft, or inlet 
  plugged

Pump delivers insufficient capacity

1.  Incorrect low voltage
4.  Ecessive inflow or pump not properly sized for 
  application
5.  Discharge restricted
6.  Check valve partially closed or installed backwards
7.   Shut-off valve closed
8.  Impeller jammed or loose on shaft, or inlet 
  plugged
9.  Pump may be air locked causing pump not to flow
10. Pump running backwards

Pump cycles too frequently or runs periodically 

when fixtures are not in use

6.  Check valve partially closed or installed backwards
11.  Fixtures are leaking
15. Ground water entering basin

Pump shuts off and turns on independent of 

switch, (trips thermal overload protector). 

CAUTION!

 Pump may start unexpectedly. 

Disconnect power supply.

1.  Incorrect low voltage
4.  Ecessive inflow or pump not properly sized for 
  application
8.  Impeller jammed or loose on shaft, or inlet 
  plugged
12. Excessive water temperature (internal 
  protection only)

Pump operates noisily or vibrates excessively

2c. Worn bearings, motor shaft bent
5.  Debris in impeller cavity or broken impeller
10. Pumprunning backwards
13. Piping attachments to building structure too 
  loose or rigid

NOTE: 

 Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied 

accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty.

PF4SCC, 4SCD, 4SCE, 4SCF    

      

         

 

 Submersible Cutter Pumps

Содержание PF4SCC Series

Страница 1: ...SCF 4 2 8 9 17 7 29 9HP 3PH 230 460V 1150 1750 RPM 60 Hz Series PF4SCC 4 2 4 8HP 3PH 230 460V 1150 1750 RPM 60 Hz Series PF4SCD 4 2 4 8 7 1HP 3PH 230 460V 1150 1750 RPM 60 Hz Series PF4SCE 4 2 12 9 17...

Страница 2: ...gers in pump with power connected The cuting mechanism is VERY SHARP Be extremely careful when servicing and or repairing the pump Always wear eye protection when working on pumps Do not wear loose cl...

Страница 3: ...nless Steel SEAL Tandem Mechanical Oil Filled Reservoir Upper Carbon Stainless Buna N Lower Tungsten Carbide Tungsten Carbide Buna N SEAL PLATE Cast Iron POWER CORD 30 ft cord pressure grommet MOTOR N...

Страница 4: ...0 457 0 57 PF4SCC4246 4 2 460 3 1150 100 6 4 31 5 2 45 G 4G1 5mm2 14 4 SO 0 457 0 57 PF4SCC4834 4 8 230 3 1750 100 14 4 80 1 21 H 4G1 5mm2 14 4 SO 0 457 0 57 PF4SCC4844 4 8 460 3 1750 100 7 2 40 1 21...

Страница 5: ...5 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PF4SCC 1150 RPM Submersible Cutter Pumps...

Страница 6: ...6 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCC 1750 RPM Submersible Cutter Pumps Performance...

Страница 7: ...SCD4834 4 8 230 3 1750 100 14 4 80 H 1 21 4G1 5mm2 14 4 SO 0 453 0 57 PF4SCD4844 4 8 460 3 1750 100 7 2 40 H 1 21 4G1 5mm2 14 4 SO 0 453 0 57 PF4SCD7134 7 1 230 3 1750 100 19 4 114 H 1 65 4G1 5mm2 14...

Страница 8: ...8 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCD 1150 RPM Submersible Cutter Pumps Performance...

Страница 9: ...9 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCD 1750 RPM Submersible Cutter Pumps Performance...

Страница 10: ...SCE12934 12 9 230 3 1750 132 35 4 230 J 0 48 4G6mm2 10 4 SO 0 67 0 75 PF4SCE12944 12 9 460 3 1750 132 17 7 115 J 0 48 4G6mm2 10 4 SO 0 67 0 75 PF4SCE17734 17 7 230 3 1750 132 45 8 292 H 0 41 4G6mm2 10...

Страница 11: ...11 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCE 1150 RPM Submersible Cutter Pumps Performance...

Страница 12: ...12 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCE 1750 RPM Submersible Cutter Pumps Performance...

Страница 13: ...CF8946 8 9 460 3 1150 132 12 8 75 H 0 64 4G6mm2 8 4 SO 0 67 0 78 PF4SCF17734 17 7 230 3 1750 132 45 8 292 H 0 41 4G6mm2 8 4 SO 0 67 0 78 PF4SCF17744 17 7 460 3 1750 132 22 9 146 H 0 41 4G6mm2 8 4 SO 0...

Страница 14: ...14 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCF 1150 RPM Submersible Cutter Pumps Performance...

Страница 15: ...15 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCF 1750 RPM Submersible Cutter Pumps Performance...

Страница 16: ...id level should never be less than above the pump s volute See Figure 1 ThecutterpumpsareNOTdesignedtorun dry ThecasingMUSTbesubmerged Installation The cutter pumps can be installed in a wet well util...

Страница 17: ...e Sensor To detec any moisture present a normally open N O probe is installed in the seal chamber The probe should be connected in series to an alarm device or motor starter coil to alert the operator...

Страница 18: ...t electrical power to pump Disassembly Cutter Impeller Remove cap screws 45 and washer 47 from volute 40 Lift motor from volute 40 Clean out volute and check impeller for pitting or wear To replace im...

Страница 19: ...USE IDENTIFICATION TAG ON EACH LEAD FIGURE 4 THREE PHASE 230 VOLT AC Power Cable Motor Lead Number G Ground G L1 or W1 1 7 L2 or W2 2 8 L3 or W3 3 9 T4 T5 T6 Together FIGURE 4 THREE PHASE 460 VOLT AC...

Страница 20: ...ain it is seated in the retainer and not cocked or resting on bellows tail Slide retaining ring 10D over shaft and let rest on spring 10C Upper Seal Clean and oil seal cavity in bearing bracket 3 Ligh...

Страница 21: ...Slide lower bearing and motor assembly into the bearing bracket 3 until bearing seats on the bottom Position bearing cap on some models on bearing bracket insert screws 19 with washers 20 and tighten...

Страница 22: ...flopumps com Figure 6 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PF4SCC 4SCD 4SCE 4SCF 100...

Страница 23: ...UMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PF4SCF 180 Mtr Frame...

Страница 24: ...dia 26 1 Screw H M4 x 6 H M4 x 6 H M4 x 6 27 1 Washer M 4 N M 4 N M 4 N 29 1 Power cable PF0 1852301 11X4G1 5 PF0 1852322 4G6 PF0 1852341 4G10 30 1 Ground 31 3 Wire connector 32 2 Cable connector PF0...

Страница 25: ...rt Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PF4SCC 4SCD 4SCE 4SCF Submersible Cutter Pumps Cutter Impeller item 41 Imp...

Страница 26: ...26 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PF4SCC 4SCD 4SCE 4SCF Submersible Cutter Pumps Notes...

Страница 27: ...hree phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits and fluid temperature 13...

Страница 28: ...od that has not been installed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following...

Отзывы: