10
Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com
MODEL
HP
VOLT/
PH
RPM
MTR
FRAME
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
NEMA
START
CODE
WINDING
RESISTANCE
(in ohms, for 1 coil)
CORD
CORD
O.D.
PF4SCE4236
4.2
230/3
1150
100
12.8
63
G
2.45
4G1.5mm
2
(14/4, SO)
0.453
(0.57)
PF4SCE4246
4.2
460/3
1150
100
6.4
31.5
G
2.45
4G1.5mm
2
(14/4, SO)
0.453
(0.57)
PF4SCE12934
12.9
230/3
1750
132
35.4
230
J
0.48
4G6mm
2
(10/4, SO)
0.67
(0.75)
PF4SCE12944
12.9
460/3
1750
132
17.7
115
J
0.48
4G6mm
2
(10/4, SO)
0.67
(0.75)
PF4SCE17734
17.7
230/3
1750
132
45.8
292
H
0.41
4G6mm
2
(10/4, SO)
0.67
(0.75)
PF4SCE17744
17.7
460/3
1750
132
22.9
146
H
0.41
4G6mm
2
(10/4, SO)
0.67
(0.75)
Control cable sizes for all models is, 4G1.5mm
2
, 0.457 O.D. (14/3, SO, 0.53 O.D.)
NOTE: The use of a 4” Break Away Fitting is required with these pumps.
NOTE: A relay is required for use with Moisture Sensor, see Page 25.
PF4SCE
Submersible Cutter Pumps
Specifications