3/4 HP Shallow Well Jet Pump

5

Visit www.princessauto.com for more information

8458788

V 3.0

PARTS IDENTIFICATION

WARNING! Do not operate the tool if any part is missing. Replace the missing part before operating. Failure to 

do so could result in a malfunction and personal injury.

Remove the parts and accessories from the packaging and inspect for damage. Make sure that all items in the parts 

list are included.

Contents:

 •  Shallow Well Jet Pump

A  1-1/4 in. NPT Suction Port

B  1 in. NPT Discharge Port

C  Junction Box

D  Drain Plug

E  1/2 in. Priming Port

F  Pressure Switch

ASSEMBLY

When this manual refers to a part number, it refers to the included Parts List section.

PRE-INSTALLATION

The following materials may be required to install the pump.

•  PVC cement (if plastic pipe is used) 

•  Thread tape

•  Pipe, pipe couplings and fittings 

•  1 in. nipple (for discharge)

•  1 in. tee or 90° elbow (for discharge)

•  1 in. pipe plug if tee is used

•  1-1/4 in. foot valve (for cased wells) 

•  Single pipe well seal for 1-1/4 in. pipe (cased or dug wells)

•  Copper electrical wire (See Wiring Instructions) 

INSTALLATION

WIRING INSTRUCTIONS

WARNING! Meet national electrical code and local codes for all wiring. Improper wiring may lead to a fatal 

electric shock. A licenced electrician should perform all wiring involved with this pump.

Installation requires wiring components into the pump. Ground the motor before connecting it to an electrical power 

source to avoid an electric shock. Do not use a gas supply line to ground the pump.

Make certain that the power supply conforms to the electrical specifications of the motor supplied. Supply voltage 

must be within 10% of nameplate voltage (see Specifications). Incorrect voltage can cause a fire or seriously 

damage motor. 

The user may wish to create a permanent connection between the pump and power source. Do not use an extension 

cord or attempt to splice wires for a permanent connection. A certified junction box is a safer choice. 

To reduce the risk of electric shock, install motor and all electrical components above the top grade level of the 

sump. This pump is not submersible.

Содержание 8458788

Страница 1: ...User Manual 8458788 Please read and understand all instructions before use Retain this manual for future reference V 3 0 3 4 HP Shallow Well Jet Pump E308498...

Страница 2: ...Diffusor Thermoplastic Dedicated Priming Port Power Cord Length 53 in 135 cm FLOW RATES Maximum Lift Head Shallow Well Applications 25 ft 7 62 m or less Max Flow Rate 960 GPH LIFT in feet 5 10 15 20...

Страница 3: ...cted situations SPECIFIC SAFETY PRECAUTIONS 1 Do not insert a finger or any object into the pump or motor openings 2 The pump is non submersible Keep the motor dry at all times Protect the motor from...

Страница 4: ...ord plug directly to the power supply whenever possible Use extension cords or surge protectors only when the tool s power cord cannot reach a power supply from the work area see below 2 Do not operat...

Страница 5: ...sed wells Single pipe well seal for 1 1 4 in pipe cased or dug wells Copper electrical wire See Wiring Instructions INSTALLATION WIRING INSTRUCTIONS WARNING Meet national electrical code and local cod...

Страница 6: ...pipes 2 Attach a 1 in pipe to the pump s discharge port 3 Attach the suction pipe to the front of the pump with a union connector A union connector makes servicing the pump easier Leave room to use w...

Страница 7: ...er replace starting switch 4 Disconnect power and file contacts with emery board or nail file Motor runs hot and overload kicks off 1 Motor is wired incorrectly 2 Voltage is too low 3 Pump cycles too...

Страница 8: ...pressure tank is waterlogged and has no air cushion 2 Pipes leak 3 Faucets or valves are open 4 Foot valve leaks 5 Pressure switch is out of adjustment 6 Air charge too low in pre charged tank 1 Drai...

Страница 9: ...Jet Pump 9 Visit www princessauto com for more information 8458788 V 3 0 PARTS BREAKDOWN PARTS LIST PART DESCRIPTION A O ring Nozzle Venturi Kit B Diffuser C Locking Nut Gasket Kit D Impeller E O rin...

Страница 10: ...3 4 HP Shallow Well Jet Pump 10 For technical questions call 1 800 665 8685 8458788 V 3 0...

Страница 11: ...Manuel d utilisateur Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Pompe jet de 3 4 CV pour puits peu pr...

Страница 12: ...foulement 2 54 cm 1 po Pression nominale max 50 lb po carr Construction Rev tement Rev tement en poudre Corps du moteur Aluminium Corps de pompe Fonte Arbre Acier inoxydable Rotor et diffuseur Thermop...

Страница 13: ...lisation CSA ou l American National Standards Institute ANSI QUIPEMENT DE PROTECTION PERSONNEL 1 Portez toujours des lunettes antiprojections qui offrent une protection frontale et lat rale pour les y...

Страница 14: ...un syst me de refoulement ferm La pompe peut surchauffer endommageant ainsi les joints et provoquant une situation propice aux blessures par br lure Amorcez la pompe avec de l eau avant le d marrage...

Страница 15: ...t de la zone de travail de l outil pendant son utilisation Le cordon doit toujours se trouver derri re l outil d Tenez le cordon l cart de la chaleur de l huile des rebords coupants ou des pi ces mobi...

Страница 16: ...asse Assurez vous que la source d nergie est conforme aux sp cifications lectriques du moteur fourni La tension d alimentation lectrique doit se situer 10 pr s de la tension indiqu e sur la plaque sig...

Страница 17: ...d amor age 3 R installez le bouchon d amor age et serrez la main 4 D marrez la pompe L appareil devrait pomper l eau en de de 30 secondes Sinon arr tez la pompe et r p tez les tapes 1 3 Lors de la pr...

Страница 18: ...e avant de rechercher d autres causes D vissez le bouchon d amor age et d terminez si de l eau se trouve dans le trou d amor age 1 La pompe dans une nouvelle installation ne s est pas amorc e cause de...

Страница 19: ...et n a pas de coussin d air 2 Les tuyaux ont des fuites 3 Des robinets ou des soupapes sont ouverts 4 La soupape de pied a des fuites 5 Le pressostat est d r gl 6 Charge d air trop faible dans le r se...

Страница 20: ...questions techniques appelez le 1 800 665 8685 8458788 V 3 0 R PARTITION DES PI CES LISTE DES PI CES No DE PI CE DESCRIPTION A Joint torique buse trousse venturi B Diffuseur C Contre crou trousse de...