3/4 HP Shallow Well Jet Pump

3

Visit www.princessauto.com for more information

8458788

V 3.0

WORK AREA

1.  Operate in a safe work environment. Keep your work area clean, well lit and free of distractions.

2.  Keep anyone not wearing appropriate safety equipment away from the work area.

3.  Do not install or use in the presence of flammable gases or liquids.

PERSONAL SAFETY  

CAUTION! Wear personal protective equipment approved by the Canadian Standards Association (CSA) or 

American National Standards Institute (ANSI).

PERSONAL PROTECTIVE EQUIPMENT

1.  Always wear impact safety goggles that provide front and side protection for the eyes. 

2.  Wear gloves that provide protection based on the work materials or to reduce the effects of vibration.

3.  Non-skid footwear is recommended to maintain footing and balance in the work environment.

4.  Wear steel toe footwear or steel toe caps to prevent injury from falling objects. 

5.  Wear protective clothing designed for the work environment. 

PERSONAL PRECAUTIONS

Control the device, personal movement and the work environment to avoid personal injury or damage to the device. 

1.  Do not operate any device when tired or under the influence of drugs, alcohol or medications.

2.  Avoid wearing clothes or jewelry that can become entangled with the moving parts of the device.  Keep long 

hair covered or bound.

3.  Do not overreach when operating the device. Proper footing and balance enables better control in 

unexpected situations.

SPECIFIC SAFETY PRECAUTIONS 

1.  Do not insert a finger or any object into the pump or motor openings.

2.  The pump is non-submersible. Keep the motor dry at all times. Protect the motor from wet weather.

3.  Do not handle the pump motor with wet hands or when standing on a wet or damp surface

4.  The motor has built-in thermal protection. This protects the motor against burnout due to low voltage, high 

voltage and other causes such as an overload. The device is automatic and resets itself once the temperature 

has dropped to a safe point. Frequent tripping of the device indicates trouble in the motor or power lines. 

Discontinue use until a qualified electrician has inspected the pump.

5.  Do not pump hot liquids. This will overheat the pump and the thermal protection system will shut the pump 

down until it has cooled down.

6.  This pump is designed to handle clear water. Any of the following can clog the pump or damage the  

pump system:

a.  Physical obstruction such as sand, dirt, debris or water scale/rust.

b.  Caustic liquids like salt water, brine, laundry discharge or any other liquid containing caustic chemicals 

and/or foreign materials. 

c.  Flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc.

7.  Never run the pump dry or against a closed discharge. The pump may overheat, damaging the seals and 

creating a situation where a burn injury can result. Prime the pump with water before starting.

8.  Do not allow pump or any other system component to freeze, as this can damage the pump  

during operation.

9.  Do not run the pump dry. This will cause cavitation in the pump mechanism and can damage the  

pump beyond repair.

Содержание 8458788

Страница 1: ...User Manual 8458788 Please read and understand all instructions before use Retain this manual for future reference V 3 0 3 4 HP Shallow Well Jet Pump E308498...

Страница 2: ...Diffusor Thermoplastic Dedicated Priming Port Power Cord Length 53 in 135 cm FLOW RATES Maximum Lift Head Shallow Well Applications 25 ft 7 62 m or less Max Flow Rate 960 GPH LIFT in feet 5 10 15 20...

Страница 3: ...cted situations SPECIFIC SAFETY PRECAUTIONS 1 Do not insert a finger or any object into the pump or motor openings 2 The pump is non submersible Keep the motor dry at all times Protect the motor from...

Страница 4: ...ord plug directly to the power supply whenever possible Use extension cords or surge protectors only when the tool s power cord cannot reach a power supply from the work area see below 2 Do not operat...

Страница 5: ...sed wells Single pipe well seal for 1 1 4 in pipe cased or dug wells Copper electrical wire See Wiring Instructions INSTALLATION WIRING INSTRUCTIONS WARNING Meet national electrical code and local cod...

Страница 6: ...pipes 2 Attach a 1 in pipe to the pump s discharge port 3 Attach the suction pipe to the front of the pump with a union connector A union connector makes servicing the pump easier Leave room to use w...

Страница 7: ...er replace starting switch 4 Disconnect power and file contacts with emery board or nail file Motor runs hot and overload kicks off 1 Motor is wired incorrectly 2 Voltage is too low 3 Pump cycles too...

Страница 8: ...pressure tank is waterlogged and has no air cushion 2 Pipes leak 3 Faucets or valves are open 4 Foot valve leaks 5 Pressure switch is out of adjustment 6 Air charge too low in pre charged tank 1 Drai...

Страница 9: ...Jet Pump 9 Visit www princessauto com for more information 8458788 V 3 0 PARTS BREAKDOWN PARTS LIST PART DESCRIPTION A O ring Nozzle Venturi Kit B Diffuser C Locking Nut Gasket Kit D Impeller E O rin...

Страница 10: ...3 4 HP Shallow Well Jet Pump 10 For technical questions call 1 800 665 8685 8458788 V 3 0...

Страница 11: ...Manuel d utilisateur Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Pompe jet de 3 4 CV pour puits peu pr...

Страница 12: ...foulement 2 54 cm 1 po Pression nominale max 50 lb po carr Construction Rev tement Rev tement en poudre Corps du moteur Aluminium Corps de pompe Fonte Arbre Acier inoxydable Rotor et diffuseur Thermop...

Страница 13: ...lisation CSA ou l American National Standards Institute ANSI QUIPEMENT DE PROTECTION PERSONNEL 1 Portez toujours des lunettes antiprojections qui offrent une protection frontale et lat rale pour les y...

Страница 14: ...un syst me de refoulement ferm La pompe peut surchauffer endommageant ainsi les joints et provoquant une situation propice aux blessures par br lure Amorcez la pompe avec de l eau avant le d marrage...

Страница 15: ...t de la zone de travail de l outil pendant son utilisation Le cordon doit toujours se trouver derri re l outil d Tenez le cordon l cart de la chaleur de l huile des rebords coupants ou des pi ces mobi...

Страница 16: ...asse Assurez vous que la source d nergie est conforme aux sp cifications lectriques du moteur fourni La tension d alimentation lectrique doit se situer 10 pr s de la tension indiqu e sur la plaque sig...

Страница 17: ...d amor age 3 R installez le bouchon d amor age et serrez la main 4 D marrez la pompe L appareil devrait pomper l eau en de de 30 secondes Sinon arr tez la pompe et r p tez les tapes 1 3 Lors de la pr...

Страница 18: ...e avant de rechercher d autres causes D vissez le bouchon d amor age et d terminez si de l eau se trouve dans le trou d amor age 1 La pompe dans une nouvelle installation ne s est pas amorc e cause de...

Страница 19: ...et n a pas de coussin d air 2 Les tuyaux ont des fuites 3 Des robinets ou des soupapes sont ouverts 4 La soupape de pied a des fuites 5 Le pressostat est d r gl 6 Charge d air trop faible dans le r se...

Страница 20: ...questions techniques appelez le 1 800 665 8685 8458788 V 3 0 R PARTITION DES PI CES LISTE DES PI CES No DE PI CE DESCRIPTION A Joint torique buse trousse venturi B Diffuseur C Contre crou trousse de...

Отзывы: