ELECTRICAL SAFETY

DANGER! Hazardous voltage can shock, burn or cause death. Ground the pump before connecting to power 

supply. Disconnect power before working on any part of the pump.

IMPORTANT! All wiring should be performed by a licenced electrician.

1.  Protect yourself against electric shocks when working on electrical equipment. Avoid body contact with 

grounded surfaces such as pipes, radiators, cooking stoves and refrigerators. There is an increased chance 

of electrical shock if your body is grounded.

2.  Do not disconnect the power cord in place of using the ON/OFF switch on the device. This will prevent an 

accidental startup when the power cord is plugged into the power supply. 

3.  Do not alter any parts of the device or accessories. All parts and accessories are designed with built-in safety 

features that may be compromised if altered.

4.  Make certain that power source conforms to requirements of your equipment.

5.  When wiring an electrically driven device, follow all electrical and safety codes, as well as the most recent 

Canadian Electrical Code (CE) and Canadian Centre for Occupational Health and Safety (CCOHS).

POWER CORD

WARNING! Risk of electric shock. This pump is supplied with a grounding conductor and three prong ground 

attachment plug. To reduce the risk of electric shock, be certain that it is connected to a properly  

grounded receptacle. 

1.  Insert the power cord plug directly to the power supply whenever possible. Use extension cords or surge 

protectors only when the tool’s power cord cannot reach a power supply from the work area (see below).

2.  Do not operate this tool if the power cord is frayed or damaged as an electric shock may occur, resulting in 

personal injury or property damage. 

a.  Inspect the tool’s power cord for cracks, fraying or other faults in the insulation or plug before each use.  

b.  Discontinue use if a power cord feels more than comfortably warm while operating the tool.

c.  Have the power cord replaced by a qualified service technician   

3.  Keep all connections dry and off the ground to reduce the risk of electric shock. Do not touch plug  

with wet hands.

4.  Prevent damage to the power cord by observing the following:

a.  Never use the cord to carry the tool.

b.  Do not pull on the cord to disconnect the plug from an outlet.

c.  Keep the power cord clear of the tool and the tool’s work path while in operation. The cord should always 

stay behind the tool.

d.  Keep cord away from heat, oil, sharp edges or moving parts.

e.  Do not allow people, mobile equipment or vehicles to pass over unprotected power cords. 

i.  Position power cords away from traffic areas.

ii.  Place cords in reinforced conduits.

iii.  Place planks on either side of the power cord to create a protective trench.

USE AND CARE OF DEVICE

1.  Use the correct device for the job. This device was designed for a specific function.  Do not modify or alter 

this device or use it for an unintended purpose.

2.  Avoid unintentional starts. Be sure that the ignition switch is in the neutral or OFF position when not in use 

or before connecting it to any power source. 

Содержание 8458788

Страница 1: ...User Manual 8458788 Please read and understand all instructions before use Retain this manual for future reference V 3 0 3 4 HP Shallow Well Jet Pump E308498...

Страница 2: ...Diffusor Thermoplastic Dedicated Priming Port Power Cord Length 53 in 135 cm FLOW RATES Maximum Lift Head Shallow Well Applications 25 ft 7 62 m or less Max Flow Rate 960 GPH LIFT in feet 5 10 15 20...

Страница 3: ...cted situations SPECIFIC SAFETY PRECAUTIONS 1 Do not insert a finger or any object into the pump or motor openings 2 The pump is non submersible Keep the motor dry at all times Protect the motor from...

Страница 4: ...ord plug directly to the power supply whenever possible Use extension cords or surge protectors only when the tool s power cord cannot reach a power supply from the work area see below 2 Do not operat...

Страница 5: ...sed wells Single pipe well seal for 1 1 4 in pipe cased or dug wells Copper electrical wire See Wiring Instructions INSTALLATION WIRING INSTRUCTIONS WARNING Meet national electrical code and local cod...

Страница 6: ...pipes 2 Attach a 1 in pipe to the pump s discharge port 3 Attach the suction pipe to the front of the pump with a union connector A union connector makes servicing the pump easier Leave room to use w...

Страница 7: ...er replace starting switch 4 Disconnect power and file contacts with emery board or nail file Motor runs hot and overload kicks off 1 Motor is wired incorrectly 2 Voltage is too low 3 Pump cycles too...

Страница 8: ...pressure tank is waterlogged and has no air cushion 2 Pipes leak 3 Faucets or valves are open 4 Foot valve leaks 5 Pressure switch is out of adjustment 6 Air charge too low in pre charged tank 1 Drai...

Страница 9: ...Jet Pump 9 Visit www princessauto com for more information 8458788 V 3 0 PARTS BREAKDOWN PARTS LIST PART DESCRIPTION A O ring Nozzle Venturi Kit B Diffuser C Locking Nut Gasket Kit D Impeller E O rin...

Страница 10: ...3 4 HP Shallow Well Jet Pump 10 For technical questions call 1 800 665 8685 8458788 V 3 0...

Страница 11: ...Manuel d utilisateur Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Pompe jet de 3 4 CV pour puits peu pr...

Страница 12: ...foulement 2 54 cm 1 po Pression nominale max 50 lb po carr Construction Rev tement Rev tement en poudre Corps du moteur Aluminium Corps de pompe Fonte Arbre Acier inoxydable Rotor et diffuseur Thermop...

Страница 13: ...lisation CSA ou l American National Standards Institute ANSI QUIPEMENT DE PROTECTION PERSONNEL 1 Portez toujours des lunettes antiprojections qui offrent une protection frontale et lat rale pour les y...

Страница 14: ...un syst me de refoulement ferm La pompe peut surchauffer endommageant ainsi les joints et provoquant une situation propice aux blessures par br lure Amorcez la pompe avec de l eau avant le d marrage...

Страница 15: ...t de la zone de travail de l outil pendant son utilisation Le cordon doit toujours se trouver derri re l outil d Tenez le cordon l cart de la chaleur de l huile des rebords coupants ou des pi ces mobi...

Страница 16: ...asse Assurez vous que la source d nergie est conforme aux sp cifications lectriques du moteur fourni La tension d alimentation lectrique doit se situer 10 pr s de la tension indiqu e sur la plaque sig...

Страница 17: ...d amor age 3 R installez le bouchon d amor age et serrez la main 4 D marrez la pompe L appareil devrait pomper l eau en de de 30 secondes Sinon arr tez la pompe et r p tez les tapes 1 3 Lors de la pr...

Страница 18: ...e avant de rechercher d autres causes D vissez le bouchon d amor age et d terminez si de l eau se trouve dans le trou d amor age 1 La pompe dans une nouvelle installation ne s est pas amorc e cause de...

Страница 19: ...et n a pas de coussin d air 2 Les tuyaux ont des fuites 3 Des robinets ou des soupapes sont ouverts 4 La soupape de pied a des fuites 5 Le pressostat est d r gl 6 Charge d air trop faible dans le r se...

Страница 20: ...questions techniques appelez le 1 800 665 8685 8458788 V 3 0 R PARTITION DES PI CES LISTE DES PI CES No DE PI CE DESCRIPTION A Joint torique buse trousse venturi B Diffuseur C Contre crou trousse de...

Отзывы: