- 22 -
0500_GB-Rückwand_563
GB
Variant with Select-Control operation
Attention!
Compressed air is used to lower and close
the tailgate
- Danger of crushing when closing
• In order to reduce or increase the
pressure in the gas container a
special filling and checking device
is necessary (M).
Pressure in the gas container: 25
bar Nitrogen (N).
• This work may only be carried out by customer service
or a specialist.
See also “Alter pressure in gas container “ in chapter
“CUTTER UNIT”
For operation see chapter “SELECT-CONTROL
Preselection”
Do not stand underneath the raised tail
gate!
- Opening and closing is effected hydraulically from the
tractor seat.
- Locking takes place automatically.
- Tailgate must be closed when driving on the road.
Attention!
Nobody should
be within the
swinging range
of the tail gate
when opening and
closing!
Variant with DIRECT-CONTROL operation
The tailgate’s own weight is used to lower it to position
C. No other pressure is used.
Only when in this position (C) is the hydraulic function
activated through switch (56) and the tailgate is closed
under pressure.
For operation see chapter “DIRECT-CONTROL
operation”
hydraulic opening and closing of the tail gate
Safety device for closing of tailgate
G
C
56
125-04-17
ca.
100
mm
TailgaTe