Rear Mount Upgrade Kit 

 
There are plenty of upgrade kits of XP-3000/3300 series for choice. To install 
these  upgrade  kits,  please  refer  the  installation  guide  of  each  kit.  For  some 
interface  such  as  serial  ports  and  VGA  ports,  please  remember  to  enable  the 
power supply of the main unit for the upgrade kit if the serial or VGA interface 
model is used.  
 
The power supply in the I/O port must be disabled if it is no longer to support 
these  intended  devices  otherwise 

any  damage  or  loss  caused  consequently 

shall be out of product warranty! 

 

Customer Display 

 
In  order  to  communicate  the  transaction  total  to 
the  customer  conveniently,  there  are  optional 
upgrades  kits  such  as  PD-330  and  PD-2606  are 
the  rear  mount  customer  display  kits  for  XP-
3000/3300  series.  Counter  space  saving  design 
with 2*20 VFD (PD-2606) and 2*20 LCD (PD-330) provides the clearest view 
for  customers.  In  addition,  real  base  mount  graphic  STN  LCD  pole  display 

PD-309/  309U/  2605/  2605U/  7614/  7624/ 
PD7634 

which 

support 

traditional/simplify 

Chinese  and  Arabic  language  can  be  integrate  to 
the  XP-3000/3300  series  for  more  applications. 
For installation of these customer displays, please 
refer to the user manual of each display or contact 
local authorise technician.  
 

 

2

nd

 LCD Panel 

 

There  are  two  sizes  of  2

nd

  monitor  can  integrate  into  XP-3000/3300  series 

which  are  12”  2

nd

  LCD  LM/TM-2212(screen  resolution  is  1024  x  768)  TM-

2212  is  a  12”  LCD  touch  monitor  which  can  mount  a  magnetic  stripe  reader 
for customer use to. 
 
The VGA port in the XP-3000/3300 system supports 
either  a  rear  mount  2

nd

  display  or  a  separately 

connected LCD monitor or touch monitor. To support 

Содержание XP-3000 Series

Страница 1: ...fits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory...

Страница 2: ...the busiest situation XP 3000 3300 Series applies Intel Pine View CPU technology fast speed Ethernet as well as plenty of connects ports of USB Serial VGA and CR ports It also integrated with thermal...

Страница 3: ...Page 2 INTRODUCTION PRODUCT PICTURES Front Views Side Views Rear Bottom Views 1 2 3 4 5 6 7 8 9 10 11 14 15 16 17 9 12 13...

Страница 4: ...Exit 14 Bottom plate compression lock 15 Bottom plate tenon 16 Rubber foot with bottom plate fixing screw 17 Bottom plate PRODUCT FEATURES Standard Features Models Item XP 3012H XP 3015H XP 3312H XP 3...

Страница 5: ...imum Paper roller diameter 80mm Paper thickness Less then 86 m LCD panel tilt angle 14 55 degree Table Summary of features Models Item XP 3012E XP 3015E XP 3312E XP 3315E LCD Display TFT LCD Panel Dig...

Страница 6: ...tems Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR2 SODIMM memory expansion up to 2GB...

Страница 7: ...ple push on the switch in 10 sec may turn off the power Note There must always be at least 10 seconds waiting before switching on again once the system is powered off successfully Brightness Control I...

Страница 8: ...video memory size is default in 128 MB and can be set to be 64 MB VGA Port The VGA port in the XP 3000 3300 system supports either a rear mount 2nd display or a separately connected LCD monitor or tou...

Страница 9: ...mouse at the point when the touch panel is touched If the point touched is dragged across the screen surface it works as the mouse drag and drop feature If the point is touched released and touched wi...

Страница 10: ...e that the push lock button in the lock release lever When the LCD panel needs to be push or pull from the most rear end please press the push lock and the lock release lever at same time then the LCD...

Страница 11: ...in order to reduce the paper loss adjustable function please see following chapter Printer setup The printer will leave the advance paper in 4 8 mm long for each print It is highly suggested to print...

Страница 12: ...ard s movement can be two way of the slot the reading process should be passing through whole slot horizontally A non standard card recorded without complete degaussing prior to recovery may accept on...

Страница 13: ...e at right Next please unfasten these two screws which fasten the UPS bracket and take out the bracket as shown in the lower left picture Please take it out and place it in the battery compartment at...

Страница 14: ...and pull up the terminal carefully than you will see the I O plate I O Plate View A 2x Serial Port RS 232 COM1 2 B 1x Serial Port RJ 45 COM3 C 1x LAN Port D 4x USB Ports E 1x CR Ports F 1x VGA Port D...

Страница 15: ...connector be screwed into place once seated Please make sure that each connector has to be connected to the right device in the right way CAUTION On doing any insertion or extraction of any connector...

Страница 16: ...t customer display kits for XP 3000 3300 series Counter space saving design with 2 20 VFD PD 2606 and 2 20 LCD PD 330 provides the clearest view for customers In addition real base mount graphic STN L...

Страница 17: ...he CR port in XP system This cable has a 6 pole plug at one end and an 8 pole plug at the other The 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear o...

Страница 18: ...on This terminal must NOT be operated in an environment with restricted ventilation There must be at least 25 mm air clearance around any top or side ventilation holes with a free flow of air around t...

Страница 19: ...iately A larger external battery may be connected to give an extended operation Please check your dealer about this capability when required WARNING If there are any signs of over charging or leakage...

Страница 20: ...in system jumper setting and printer parameter setting However such support is limited to the application of specific Posiflex peripherals and must be disabled when the Posiflex peripherals are disco...

Отзывы: