38
ELECTRIC WINCH MOUNTED TO WALL
ELECTRIC WINCH MOUNTED ON MASONRY WALL
ELECTRIC WINCH MOUNTED ON STUD WALL (OR MASONRY
WALL FOR HORIZONTAL APPLICATION)
*WHEN LOCATING ELECTRIC WINCH ON WALL,
CHECK TO ENSURE WINCH WILL NOT INTERFERE
WITH THE MODEL NO. 219'S CROSS FLATS ON
BACKSTOP WHEN BACKSTOP IS FOLDED UP
ELECTRICIAN NOTE:
MOUNT 4" Sq. JUNCTION
BOX WITHIN 3'-0" OF
ELECTRIC WINCH
DRILL AND COUNTERBORE
WOOD PADS AS SHOWN FOR
1/2" x 21/4" Lg. CARRIAGE
BOLTS - (4) PLACES.
COUNTERBORE TO A DEPTH
OF 3/16"
THRU BOLTING FOR CONCRETE OR
MASONRY WALLS. 1/2" MASONRY ANCHORS
IN HORIZONTAL GROUT LINES BY INSTALLER.
(EIGHT ANCHOR BOLTS RECOMMENDED.)
DRILL AND COUNTERBORE WOOD
PADS AS SHOWN FOR 1/2" x 21/4"
Lg. CARRIAGE BOLTS - (4) PLACES.
COUNTERBORE TO A DEPTH OF 3/16".
RECOMMEND A MINIMUM OF FOUR POSITIVE FASTENER
CONNECTIONS TO THE WALL. LAG SCREWS ARE NOT APPROVED.