Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
7
5 - UNPACKING, LIFTING AND MOVING INSTRUCTIONS
Upon receipt verify that the material received is in exact compliance with that listed on the packing slip.
When unpacking follow the instructions listed below:
- check for visible damages on the crate that could have occurred during transport
- carefully remove the packaging material
- check that pump/or accessories such as tanks, piping, valves, etc. are free from visible markings such as dents and
damage which may have occurred during transportation
- in the event of damage, report this immediately to the transport company and to POMPETRAVAINI's customer
service department.
DANGER!
Danger due to cut, prick or abrasion Take immediate actions to dispose of possible packaging parts that may
generate injuries or risks (for example edges, nails, splinters, etc.)
Organize the right management of materials subjected to controlled and differentiate disposal (for example
plastic, cartoon, polystyrene materials, etc.) according to the laws into force and to a safe local environment
management. according to the laws into force and to a safe local environment management.
If the pump will be stored, as foreseen in our Operating Manuals, we recommend a proper care to avoid oil
dropping on the ground.
The pump or assembly must ALWAYS be moved and transported in the horizontal position.
Prior to moving the unit find the following:
- total weight
- centre of gravity
- maximum outside dimensions
- lifting points location.
DANGER!
Danger due to overturning or crushing. For safe lifting to prevent material damages and/or personal injuries, it
is recommended to use ropes, or belts properly positioned on the pump and/or lifting eyebolts and make
correct movements.
Operate provided with apposite protective devices.
(For the Oilsys systems see chapter 21).
The fig. 1 and 2 show several additional examples of lifting.
Avoid lifts whereby the ropes or straps, form a triangle with the top angle over 90°(see fig. 3).
Lifting eyebolts fitted on single components of the assembly (pump or motor) should not be used to lift the total
assembly.
The fig. 4 shows several additional examples of lifting to be avoided.
CAUTION!
Possible contact with
fluids or harmful substances. Before removal after a period of operation, the pump,
together with auxiliary piping and jacketing, must be drained and decontaminated from the handled media.
Every hole and opening communicating with the inside of the pump must be properly plugged.
For removing the pump from the installation see chapter 19. Operate provided with apposite protective
devices.