7
6.1 Grounding
The device must be grounded according to EN 60728-11.
- Strip approximately 15 mm of the cable insulation of the grounding cable (4mm
2
).
- Slide the stripped end under the earth screw and tighten the screw.
7. Installation
Connection of the input signals
Connect the SAT signals directly or via splitter(s) to the SAT tuner inputs. At SAT input tuners 1, 2, 5 and 6, a 12 V
DC voltage is applied for LNB supply. DVB-T and DVB-C are connected via the terrestrial input. A 12 V supply is
optionally available at the terrestrial input tuners 4 and 8.
Please note the current consumption of each input may not exceed 250 mA. A total of
500 mA is available.
Input 4
SAT
Input 3
SAT
Input 7
SAT
Input 8
SAT
Input 2
SAT
LNB-DC
Input 1
SAT
LNB-DC
Input 6
SAT
LNB-DC
Input 5
SAT
LNB-DC
Input 1
Terr.
Input 2
Terr.
Input 3
Terr.
Input 4
Terr.
DC
Input 5
Terr.
Input 6
Terr.
Input 7
Terr.
Input 8
Terr.
DC