10
8. General programming
After connection, the device runs through an internal routine and all channels are set up according to the previously
stored data. During this time, the
Status LED
flashes green. A connection between the PXU 848 IP and the
PC/notebook is only possible after the
Status LED
permanently lights up green or orange.
8.1 Initial setup
The PXU 848 IP is configured via the Network Management System (NMS).
8.1.1 Establishing a connection via the browser
Connect the PC or notebook directly to the network management port using a suitable CATx LAN cable. The input
window appearance depends on the selected browser (Chrome, Firefox, Internet Explorer, etc.).
Notes:
PC / notebook and the IP streamer must be in the same network / IP address range.
Cookies must be accepted and JavaScript must be enabled.
Use current browser versions.
Enter the following IP address in the search bar of the web browser:
192.168.1.129
Username:
admin
Password:
password
Then click
OK
to establish the connection.
If the IP address of the IP streamer is lost or forgotten, it can be reset to the factory setting (192.168.1.129) as
following:
o
Disconnect the mains plug.
o
Press and hold button TA1 on the IP board.
o
Reconnect the mains plug.
o
Wait until the status LED flashes red / green alternately.
o
Now the IP address is reset and the button can be released.
192.168.1.129
http://192.168.1.129 verlangt einen Benutzernamen und ein Passwort. Ausgabe der Website:
„DVBIP“