25
The "Diagnostic" menu is used for service purposes and can be helpful for telephone error analysis via the
H49 (0) 7081 / 1702-0
.
In the menu header, the operating data of the device will be displayed.
Actual Operating Temperature:
approx. current environmental temperature
Total Operating Hours:
operating hours
Maximum Operating Temperature:
maximum measured environmental temperature
Critical Operating Hours:
operating hours at environmental temperature over 45°C
Note:
The temperatures shown only correspond to the current values in the case of correct, vertical
installation with a closed housing cover.
In the middle part of the menu, the input and CI parameters of each slot will be monitored. A shows the
error free function and a a possible error.
Tuner Lock:
Tuner locked to the adjusted input frequency
ASI-Sync / ASI-188 / Clipping:
Monitoring of the internal transport streams
CAM-Plugged:
Confirmation that the CAM module is plugged in
CAM-Initialized:
Confirmation that the CAM module is initialized
Descrambling:
Confirmation that the CAM module decrypted services
In the lower part, the internal function units of the channels will be monitored. A shows the error free
function and a a possible error.
Rem. Bitrate kBit/s:
Remaining bit rate per MUX channel
Total Bitrate kBit/s:
Total bit rate per MUX channel
Total Data Rate:
Total data rate of the output stream
Peak Data Rate:
Peak data rate of the output stream
The current peak value is stored hourly.
After mains disconnection restart, or relevant data-related
parameters are changed, the values are reset.
The fields
Rem. Bitrate MUX 1 - 8
are marked in colours after checking:
Green
:
More than 10000 kSym of data rate capacity remaining.
Orange
:
Fewer than 10000 kSym capacity remaining.
Red
:
Fewer than 5000 kSym capacity remaining.
1.
2.
3.