24
SANDOR QUAD ESA SMA
POLITEC | INSTALLATION MANUAL - VER.3.1
On the QUAD B RX motherboard, it is possible to configure different functional conditions, using the
10 and 5 DIP SWITCH units.
1
CH1
Transmission channel 1
2
CH2
Transmitting channel 2
3
CH3
Transmission channel 3
4
CH4
Transmission channel 4
5
BEAM 3
The first 3 RXs are active
6
BEAM 4
The first 4 RXs are active
7
BEAM 5
The first 5 RXs are active
8
BEAM 6
The 6 RXs are active
9
NO
In ON the alarm relay switches to NO when at rest, Otherwise the relay is NC
10
LED
In ON the LED indicator on the board is turned on.
10 DIP SWITCH UNIT
1
AND
In ON the barrier goes into alarm with at least 2 interrupted RX beams
2
AND 1-2
In ON the barrier goes into alarm in AND with the two RX lower beams and in
OR with the remaining ones.
WARNING:DIPs 1 and 2 cannot both be active
3
DISQ
In ON the fog "DISQUALIFICATION" function is activated.In case of fog the
barrier is inhibited, blocking the alarm relay.It self-restores as soon as the
fog has cleared.The condition information can be transferred from the
output of the dedicated terminal.
4
CRO
In ON the cross beam function is activated.
5
AMK
In ON the "ANTIMASK" and IR filter function is activated.The condition
information can be transferred from the output of the dedicated terminal.
5 DIP SWITCH UNIT
15.3 Characteristics of settings
N.B.By default the QUAD barriers with 4TX and 4RX or ESA with 6TX and 6RX, therefore in
standard configuration, are set during the factory testing phase.If it is necessary to change the
original number of Beams in the field, it is necessary to correctly set the DIP SWITCHES from 5 to
8 on the 10 unit of the QUAD B RX and QUAD B TX motherboard.