8
SANDOR QUAD ESA SMA
POLITEC | INSTALLATION MANUAL - VER.3.1
6.2 Placement and mounting
It is strongly recommended to always request and use the accessory brackets for fixing the columns,
avoiding to make holes in the aluminium structure.
WARNING:
Product warranty is invalid if there is any hole in the aluminium profile or any component
Pole mounting with SAN/PL
SAN/PL brackets allow fixing on poles type
SAN/TB1 and SAN/TB2 with a diameter of 48 -
50mm in a very simple way as seen in the figure.
•
Each column requires a minimum of 2
brackets or more if the column is very tall.
•
The poles are equipped with a base for fixing
to the floor or to the POB30 cable pit to be
cemented into the ground, also with the
function of branch junction box.
•
The connection cables enter from the lower
cover of the column, equipped with O rings
and cable glands.
Wall mounting with SAN/PL
The SAN/PL brackets also allow fixing to the
wall, in a very simple way as seen in the figure.
•
It is recommended to use these, when
protecting windows, doors, etc., along the
wall, in order to avoid small obstacles, such
as hinges, edges of the windowsills, which
could
be
in
the
beams
creating
an
attenuation of the signal.
•
Each column requires a minimum of 2
brackets or more if the column is very tall.
Wall mounting with SAN/SD
The SAN/SD brackets supplied in a kit of 2
pieces allow wall mounting and are invisible, as
seen in the figure.
•
These brackets are recommended when the
columns are placed in front of each other or
the internal optics are rotated to less than
90° horizontally.
•
Each column requires a kit consisting of two
brackets, which are fixed to the ends of the
column, leaving only the holes for wall fixing
visible.
•
Once all the installation and functional
operations have been completed, the two
covers will hide the part with the fixing
holes.