background image

PRODUCT

SANDOR

SANDOR QUAD - ESA 

SMA

Product code SANDOR QUAD ESA SMA

DOUBLE OPTIC PERIMETER BARRIER

INSTALLATION AND MOUNTING MANUAL VERSION 3.1

Содержание SANDOR QUAD ESA SMA

Страница 1: ...PRODUCT SANDOR SANDOR QUAD ESA SMA Product code SANDOR QUAD ESA SMA DOUBLE OPTIC PERIMETER BARRIER INSTALLATION AND MOUNTING MANUAL VERSION 3 1...

Страница 2: ...ng 12 10 1 Type of cable 10 2 Connecting the cables from the power supply to the barrier 11 Connections to the terminal board 14 11 1 RX Section 11 2 TX Section 12 Barrier alignment 16 12 1 Calibratio...

Страница 3: ...N B These barriers use optical synchronism The receiver must see ONLY and exclusively its transmitter MUST NOT see signals from other barriers IR lights such as photocells or flashing lights It is no...

Страница 4: ...litec there is no warranty for the end user who in the event of breakdowns or faults must contact the installer or dealer The warranty excludes aesthetic parts as well as parts subject to normal wear...

Страница 5: ...AL VER 3 1 The package contains the following components and accessories When opening the package check that everything has been included No COMPONENT 1 Aluminium profile 2 Caps 3 Transmitter Receiver...

Страница 6: ...universal circuit board housing insert and connect the radio transmitter and connect it to the barrier receiver board c Power up the barriers and program them d Test barrier operation e Place without...

Страница 7: ...in its range of action trees plants or objects that can swing or move with the wind or rain Position the barrier so that sunlight does not hit it directly near the RX sensors In any case it is necessa...

Страница 8: ...d with O rings and cable glands Wall mounting with SAN PL The SAN PL brackets also allow fixing to the wall in a very simple way as seen in the figure It is recommended to use these when protecting wi...

Страница 9: ...e controls that significantly limit false alarms as the genuine alarm signal is given by the complete interruption of the infrared signal TX RX 2 50 m 2 m TX HEATERS It is recommended to power the the...

Страница 10: ...there are plants bushes or fixed objects in the range that obstruct the signal and create grey areas Leave a corridor of 50cm for distances between columns greater than 50m TX RX TX RX DO NOT place b...

Страница 11: ...r systems and for the protection of facades as well as in the open field observing the necessary precautions given by their characteristics e g optical synchronism power supply and working distances T...

Страница 12: ...the LAR22 power supply 12Vdc 2 5A 24Vac 300W and a SANDOR QUAD ESA SMA column 4TX or 4RX The LAR22 can power up to 4 barriers at the maximum extension 6TX 6RX The LAR22 container is metallic so it mu...

Страница 13: ...own here highlight the connection from the power supply to single columns however it can also be carried out in cascade when two columns have been fixed on the same pole having duly calculated the dis...

Страница 14: ...r Vdc HTR 3 9 ALM NC alarm output GND 2 8 ALM NC alarm output Power supply 12 30 Vdc 1 7 TMP Tamper output 6 TMP Tamper output 11 Connections to the terminal board 14 SANDOR QUAD ESA SMA POLITEC INSTA...

Страница 15: ...ND 2 6 TMP Tamper output Power supply 12 30 Vdc 1 5 TMP Tamper output 15 SANDOR QUAD ESA SMA POLITEC INSTALLATION MANUAL VER 3 1 4 3 2 1 6 5 12V power supply Tamper Power supply Heaters 11 2 TX Sectio...

Страница 16: ...left of the lens Vertical orientation Horizontal orientation JOINT LOCKING SCREW N B Tighten the joint locking screw after the adjustment 12 1 Calibration using SMA system It is possible to improve th...

Страница 17: ...ge high intensity LEDs Press the TEST button on the TX optic of the corresponding column for 5 seconds in this case only the orange TEST LED will light up Orient the TX optic towards the RX optic vert...

Страница 18: ...zzer After calibration tighten the horizontal adjustment screw and exit the test function by pressing the TEST button on the TX and RX optics for 3 seconds Repeat all the operations on each beam of th...

Страница 19: ...optics and proceed with the calibration as explained but having found the maximum alignment keep the TX1 optic in test and exit the test only with RX1 then repeat the same operations with RX2 RX3 and...

Страница 20: ...barrier is in alarm AM Lit if receiving IR interference 5 DIP SWITCH UNIT FOR CONFIGURATIONS INTERVENTION TIME ADJUSTMENT TRIMMER AND RANDOM DIP 2 DISQUALIFICATION DIP 3 13 Basic functions 13 1 Basic...

Страница 21: ...walking alarms By adjusting the potentiometer anticlockwise the intervention time is increased up to 500ms In this condition the alarm of a person crossing the barrier while walking is guaranteed wit...

Страница 22: ...reen DISQUALIFICATION LED SL Green HEATERS LED HTR Yellow 2 TRIMMER Intervention time adjustment 3 10 DIP SWITCH UNIT Channel and beam selector 4 5 DIP SWITCH UNIT Function selector 5 SW4 JUMPER Heate...

Страница 23: ...ence of an unwanted modulated infrared signal ANTIMASK can be signalled on the terminal board in the presence of an attempt at masking N B Under normal operating conditions the LED must remain off If...

Страница 24: ...lower beams and in OR with the remaining ones WARNING DIPs 1 and 2 cannot both be active 3 DISQ In ON the fog DISQUALIFICATION function is activated In case of fog the barrier is inhibited blocking th...

Страница 25: ...components 1 POWER SUPPLY LED PWR Green HEATERS LED HTR Yellow 2 10 DIP SWITCH UNIT Channel and beam selector 3 SW4 JUMPER Heater power supply switch 4 TAMPER Column tamper connection 1 3 16 Appendix...

Страница 26: ...guarantee an internal temperature between 17 C and 22 C under all climatic conditions Normally off when on the heating is active On the QUAD B TX motherboard it is possible to configure different func...

Страница 27: ...on the TX optic functioning is verified The power supply of the heaters is set by default to 24V 12V can be used by changing the jumper configuration SW4 on all optics and on the QUAD B TX board The v...

Страница 28: ...heaters is set by default to 24V 12V can be used by changing the jumper configuration SW4 on all optics and on the QUAD B RX board The voltage can be both AC and DC Jumper J4 reads the value of the al...

Страница 29: ...EMPERATURE 25 C 65 C Heater kit available for temperatures down to 50 C ALIGNMENT ANGLES 20 Vertical 180 horizontal DETECTION SYSTEM OR AND 1st and 2nd AND random REMOTE CONTROL AND Random EXTERNAL SC...

Страница 30: ...separate shielded cables Check the correct sizing of the power cables Make sure there are no external light sources that interfere with the correct reading of the signal gate photocells other barrier...

Страница 31: ...ke sure that the power supply of the heaters is greater than 20 Vac at the barrier terminal board Make sure that the structure is well sealed and check that there are not already elements inside which...

Страница 32: ...of products governed by regulations in force in your area Warning Some parts of the products may contain polluting or dangerous substances which if dispersed in the environment could result in harmfu...

Отзывы: