8
ALES QUAD
POLITEC | INSTALLATION MANUAL - VER.1.2
6.2 Placement and mounting
For wall mounting, the use of spacers is recommended when protecting openings (windows, doors
etc.) along the wall, in order to avoid small obstacles (hinges, edges of windowsills etc.) that could be
in the beams creating a signal attenuation.
Pole mounting with U-shaped brackets
The supplied brackets allow mounting on poles
with a diameter of 48 - 50 mm.
•
Drill an 8mm diameter hole on the pole for
the passage of the connection cable
•
Pass the connection cable through the hole
•
Place the U-shaped brackets on the pole and
fix them to the plate with the screws
provided
•
Make the connections on the terminal board
•
After checking the alignment and correct
operation, refit the cover and tighten the
closing screw firmly.
Wall mounting with fixing plate
•
Measure the length of the barrier on the
wall drilling at the holes on the bracket
•
Loosen the plate locking screw and remove
it by sliding the plate down against the
aluminium profile of the barrier
Wall mounting with spacers
P
ass the connection cable through the hole in
the fixing plate and fix the plate to the wall with
the screws
•
Make the connections on the terminal board
•
After checking the alignment and correct
operation, refit the cover and tighten the
closing screw firmly.
WARNING:
Product warranty is invalid if there is any hole in the aluminium profile or any component