3. General warnings

4

ALES QUAD

POLITEC | INSTALLATION MANUAL - VER.1.2

This installation manual contains important information regarding safety for installation: it is 
necessary to read all the instructions before proceeding with the installation.

Keep this manual for future use. 

If you have any questions or doubts during installation, do not carry out any operations and contact
the distributor's support service.

Use of these products for purposes other than those specified in these instructions is prohibited.

You must not make any change to the components of the product unless stated in the manual in
order not to void the warranty; such operations can only lead to malfunctions; Politec assumes no
liability for malfunctions or damage due to modified products.

Depending on the specific situation of use, check for the need for additional devices: detectors or
signalling devices.

During installation, mounting and use of the product, make sure no foreign objects (solids, metals
or liquids) are able to penetrate inside the open devices.

Manufacturer's liability:Politec assumes no liability for failures resulting from incorrect installation;
lack of maintenance, incorrect assembly or use.

Politec is also not liable for incorrect or incomplete operation of the product or failure to detect
intrusion.

Warranty (summary of conditions):Politec guarantees its products for a period of 2 years from the
production date.The warranty is applied to those purchasing directly from Politec; there is no
warranty for the end user who, in the event of breakdowns or faults, must contact the installer or
dealer.

The warranty excludes aesthetic parts as well as parts subject to normal wear and parts subject to
normal consumption such as batteries and accumulators.

3.1  Additional warnings for devices powered by mains voltage

This manual is intended only for technical personnel qualified to install such devices.

Assessing the hazards that may occur during installation and use of the system, in order to achieve
complete safety, it is necessary that installation takes place in full compliance with applicable laws,
methods, rules and regulations.

Before accessing the internal terminals of the product, it is necessary to disconnect all the power
circuits.

If automatic circuit breakers or fuses trip, before resetting them it is necessary to identify the fault
and repair it.

3.2 Installation warnings

Check that all the material to be used is in excellent condition and suitable for use.

Before proceeding with the installation, check the environmental class of the products in the
"technical specifications" chapter.

Check, by comparing with the values shown in the paragraph "technical specifications", that the
range of the devices is equal to or lower than the physical distance between the barriers.

Check that the barrier is positioned in areas protected against potential impact, in flat areas and on
fixed supports to avoid oscillations.

Do not place the system components close to heat sources as they could be damaged.

Each barrier has its own operating principle: check the instructions for choosing the right position
in the respective instruction manual.

Содержание ALES QUAD 160

Страница 1: ...PRODUCT ALES QUAD ALES QUAD Product code ALES QUAD 160 ALES QUAD 250 QUADRUPLE OPTIC PERIMETER BARRIER INSTALLATION AND MOUNTING MANUAL VERSION 1 2...

Страница 2: ...tallation height 6 2 Placement and mounting 7 Evaluations before installation 9 7 1 Introduction to barriers 8 Barrier positioning 10 8 1 Precautions before installation 9 Wiring 11 9 1 Type of cable...

Страница 3: ...smitter Operation is based on the AND logical operations in other words the alarm is activated only in the event of simultaneous interruption of two superimposed beams This barrier is ideal for perime...

Страница 4: ...olitec there is no warranty for the end user who in the event of breakdowns or faults must contact the installer or dealer The warranty excludes aesthetic parts as well as parts subject to normal wear...

Страница 5: ...rything has been included COMPONENT LIST 1 Polycarbonate black cover 9 AHTR thermostat control kit present on AQ250 2 Board cover 10 Gasket 3 Optics unit 11 Fixing plate stopper 4 Dis TRG dual optics...

Страница 6: ...sal electronic board housing insert and connect the radio transmitter and connect it to the barrier receiver board c Power up the barriers and program them d Test barrier operation e Place without fix...

Страница 7: ...action trees plants or objects that can swing or move with the wind or rain Position the barrier so that sunlight does not hit it directly near the RX sensors However it is necessary to take into cons...

Страница 8: ...the plate with the screws provided Make the connections on the terminal board After checking the alignment and correct operation refit the cover and tighten the closing screw firmly Wall mounting wit...

Страница 9: ...ultiple controls that significantly limit false alarms as the genuine alarm signal is given by the complete interruption of the infrared signal TX RX TX HEATERS It is recommended to power the thermost...

Страница 10: ...e are plants bushes or fixed objects in the range that obstruct the signal and create grey areas Leave a corridor of 50cm for distances between columns greater than 50m TX RX TX RX DO NOT place barrie...

Страница 11: ...aid The sizing of the cables depends on the consumption of the columns and on the resistance of the cable itself according to the distances involved The table shows the cable cross sections and the re...

Страница 12: ...r shaped connection to avoid excessive voltage drops on the power cables The various examples shown here highlight the connection from the power supply to single columns however it can also be carried...

Страница 13: ...metres can be made In the event of joints the braid and shield connections must also be restored N B Connect the power supply negatives of the common columns It is possible to carry out this procedure...

Страница 14: ...f the lens Vertical orientation Horizontal orientation JOINT LOCKING SCREW N B Tighten the joint locking screw after the adjustment 10 1 Calibration using SMA system It is possible to improve the cali...

Страница 15: ...1 DIP on the TX motherboard to enter the test with lower optic TX1 Orient the TX optic on the column towards the RX optic vertically and horizontally acting as explained above until you find the maxim...

Страница 16: ...er optic TX2 Exit the test of the optic by setting to OFF the TEST 1 DIP on the TX motherboard Set to ON TEST 1 DIP of the TX motherboard and repeat the alignment procedure for the crossed calibration...

Страница 17: ...ters on if present SL2 Low signal upper RX optic SL1 Low signal lower RX optic SYNC Very fast flashing side with RX optic inside and wired synchronism SLOW Fog disqualification AMASK Antimask ALM On i...

Страница 18: ...ONFIGURATION LED INDICATORS POWER On if powered HTR Heaters on if present SYNC Very fast flashing side with RX optic inside and wired synchronism T2 TX2 upper optic in TEST T1 TX1 lower optic in TEST...

Страница 19: ...connected in the AQ 250 version while it is optional in the AQ 160 version in this case connect the AHTR board with the cable provided and fix it at the bottom to each TX and RX column using the scre...

Страница 20: ...e is increased up to 500ms In this condition the alarm of a person crossing the barrier while walking is guaranteed with the advantage of excluding the possibility of any false alarms e g animal cross...

Страница 21: ...ing detection with other Infrared signal with outward signalling O C NO to GND OPERATING TEMPERATURE 25 C 70 C Heater kit available for temperatures down to 50 C ALIGNMENT ANGLES 20 Vertical 180 horiz...

Страница 22: ...in the absence of fog Make sure that the power supply of the heaters is greater than 20 Vac at the barrier terminal board Check the alignment accuracy of each individual optic and if necessary carry...

Страница 23: ...ter than 20 Vac at the barrier terminal board Use the shielded cable for separate power supply and synchronism by connecting the braid to the earth Check the correct sizing of the power cables 15 Prod...

Страница 24: ...POLITEC INSTALLATION MANUAL VER 1 2 For technical support contact your security systems distributor...

Отзывы: