23
1.Disconnect the device from the power supply. Always pull only the plug, not the cord. Gather the power cord using the automatic winding button.
2. Press the lid latch downwards and pull the lid towards you, remove the lid and remove the filter.
3. Rinse the filter in a cold running water. Do not use soap or detergents!
4. Dry the filter at a room temperature for 24 hours.
5. Place back the air outlet filter (or replace it with a new one) and close the cover by inserting it into place until it clicks .
Storage
Electrical devices are stored in a closed, dry and clean room at an ambient temperature of no higher than 40 °C with relative humidity not higher than 70% and no dust,
acid or other vapours in the environment that negatively affect the materials of the electrical device.
Keep the device out of the reach of children.
In the back of the device body there is a slot for fixing the tube with the nozzle in a vertical position for storage.
9. Transportation
Electrical appliances are transported by all means of transport in accordance with the rules for the carriage of goods in force on a particular type of transport. When
transporting the device, use the original factory packaging.
Transportation of devices should exclude the possibility of direct exposure to atmospheric precipitation and aggressive environments.
10. Sale
Sales rules have not been established.
11. Troubleshooting
This table is dedicated to the most common problems occuring when using the device. If you are unable to solve the problems by your own efforts, contact the
customer support center or an authorized service center.
Trouble symptom
Causes
Troubleshooting
The device does not turn on
No power
Check that the power cord is securely
connected to the grid
The suction power is insufficient or
reduced during operation
There is a blockage in the dust collecting bag, filter,
hose or nozzle
Clean or replace the dust collecting bag and
filters. Check and remove the blockages in the
nozzle
Electrical discharges during operation
and dust sticking to the nozzle body
Static electricity due to low indoor humidity
Take measures to humidify indoor air.
Regularly hold the nozzle close to metal
objects to remove static charges
Unexpected shutdown of the device
during operation
The protective device was triggered due to
overheating of the motor
Eliminate possible causes of overheating
(clogging of the dust collector, filter, and
attachments). Allow the appliance to cool
down for at least 30 minutes before turning it
on again
The cord can not be fully wound
The cord is twisted, dirty, or wound unevenly
Pull the cord to its full length, wipe it with a
damp cloth, dry it, and wind it back evenly.
Note: At the end of the useful life of the device do not dispose of it with the ordinary household waste, but return it to an official collection point for further recycling.
Thus, you will help to save the environment.
12. Disposal requirements
According to WEEE 2012/19/EU on waste electrical and electronic equipment Directive, do not dispose of the devices with the household
waste. It should be transferred to an official separate waste collection centre.
13. Technical specifications
PVC 0786 is a household electric vacuum cleaner
Voltage: 220-240 V
Frequency: ~ 50 Hz
Maximum power: 750 W
Dust container effective volume: 2l
Class of safety – 2
Note: Due to the ongoing process of making changes and improvements, there may be some differences between the Manual and the product. The manufacturer hopes
that the user will pay attention to this.
14. Certification information
The device complies with the following EU Directives:
- 2014/30/ЕU (EMC)
- 2014/35/EU (LVD)