Section 6. Troubleshooting
If the recommendations in this section do not solve your particular problem(s), please contact your local
dealer for service.
Symptom
Possible Cause/Solution
Motor does not start.
1. Disconnect switch or circuit breaker in OFF position
2. Fuses blown or thermal overload open. Locked motor shaft
3. Motor windings burned out
4. Defective starting switch inside single-phase motor
5. Disconnected or defective wiring
6. Low voltage
Motor does not reach full speed.
1. Low voltage
2. Motor windings connected for wrong voltage on dual voltage model
Motor overheats (protect trips).
1. Low voltage
2. Motor windings connected for wrong voltage on dual voltage model
3. Inadequate ventilation
Pump delivers no water
1. Pump is not primed
2. Closed valve in suction or discharge line
3. Leakage or air into suction system
4. Impeller clogged
Low pump capacity.
1. Valve in suction or discharge line partly closed
2. Suction or discharge line partly plugged
3. Suction or discharge line too small
4. Pump running at reduced speed (see above)
5. Plugged basket in skimmer or hair and lint strainer
6. Dirty filter
7. Impeller clogged
Low pump pressure
1. Pump running at reduced speed (see above)
2. Discharge valve or inlet fittings closed too much
High pump pressure
1. Discharge valve or inlet fittings closed too much
2. Return lines too small
3. Dirty filters
Noisy pump and motor
1. Plugged basket in skimmer or strainer basket
2. Worn motor bearings
3. Valve in suction line partly closed
4. Suction line partly plugged
5. Vacuum hose plugged or too small
6. Pump not supported properly
The pump is leaking water between
the motor and pump body
1. This is caused by a damaged or failed mechanical seal. Replace the
seal
Air bubbles at inlet fittings
1. Leakage air into suction line at connections or valve stem
2. Cover gasket of hair and lint strainer needs cleaning
3. Restriction in suction line
4. Low water level in pool
Section 7. Technical Data
Model
GPM
HP
THP
RPM
Volts/ HZ
Amps
PAG100
PAG100T
60
1.00
0.75
3450
115V/60HZ
9
PAG150
PAG150T
70
1.50
1.0
12
Содержание FORZA PAG100
Страница 10: ...Page 10 ENGLISH Polaris Forza Pump Owner s Manual NOTES...
Страница 11: ...Page 11 ENGLISH Polaris Forza Pump Owner s Manual NOTES...
Страница 22: ...Page 22 FRAN AIS Pompe Polaris Forza Manuel du propri taire REMARQUES...
Страница 23: ...Page 23 FRAN AIS Pompe Polaris Forza Manuel du propri taire REMARQUES...
Страница 34: ...P gina 34 ESPA OL Bomba Polaris Forza Manual del propietario NOTAS...
Страница 35: ...P gina 35 ESPA OL Bomba Polaris Forza Manual del propietario NOTAS...