D.1.8.2 Alarm> Humidity
Path:
Home
>
Installation>
Climate>
Alarm>
Humidity
This alarm can keep under control the minimum and maximum ambient humidity level.
D. Installation - Climate alarm
Humidity setting of the Minimum alarm (absolute setting).
Below this setting the alarm is on.
Humidity setting of the Maximum alarm (absolute setting).
Above this setting the alarm is on.
Typically you would set this at 97% to indicate when the wet bulb
has become dry (when using the pysicrometric kit).
Minimum (absol. set)
(Range:
0
%
...100
%
)
Maximum (absol. set)
(Range: 0.0
%
...
97
%
...100%)
D.1.8.3 Alarm> Pressure
Path:
Home
>
Installation>
Climate>
Alarm>
Pressure
This alarm can keep under control the minimum and maximum negative air-pressure level.
Pressure set (Pascal) of the Minimum alarm (absolute setting).
Below this setting the alarm is on.
By setting
0p
the minimum pressure alarm is excluded.
Pressure set (Pascal) of the Maximum alarm (absolute setting).
Above this setting the alarm is on.
Minimum (absol. set)
(Range:
0
P
...300
P
)
Maximum (absol. set)
(Range: 0
P
...
100
P
...300
P
)
*1
Intervention of the alarm is delayed by 6 seconds.
*2
The alarm is not activated during the off ventilation period when ventilation is operated by timer
in Air exchange.
ON
*1 *2
OFF
ON
*1 *2
MINIMUM
PRESSION
ALARM
MAXIMUM
PRESSURE
ALARM
OFF
Air depression
(Pascal)
2p
fixed
2p
fixed
Minimum (absol. set)
Maximum (absol. set)
ON
OFF
MINIMUM
HUMIDITY
ALARM
Minimum (absol. set)
ON
MAXIMUM
HUMIDITY
ALARM’
Maximum (absol. set)
Ambient
humidity
OFF
0.2%
fixed
0.2%
fixed