Foreword
According to what was set in
Configuration
(see par. D.C)
Xfarm
can control up to 2 Flaps according
to following typical actioning:
> Pressure drop (thru the DP59/W pressure drop control module).
> Associative mode, without DP59/W pressure drop control module.
At each ventilation step is associated a % opening of flap (works by feedback potentiometer).
> Associative mode, without DP59/W pressure drop control module, but with 0-10V output.
> Natural Floating mode, Flap works by natural ventilation according to temperature probe.
> Natural Proportional mode, Flap works by natural ventilation according to temperature probe
(by potentiometer or by 0 -10V).
D.1.2 Flap
installation parameters
Path:
Home
>
Installation>>
Climate>
Flap
D. Installation - Flap
Influence of Blocks on Flap operation.
Normal Flap’s working can be influenced by some block condition (par. D.1.2.6).
The intervention of those blocks is visualized in
Zoom on ventilation
and in
Climate blocks
(par. F.1)