Pneumax
PTO-Driven Compressor Kit Installation Guide
Page 6 of 36
PTO installation
Follow the PTO manufacturer's installation guidelines.
Caution: Because the compressor is cooled by water from the water pump, we strongly
suggest that the compressor is only engaged while the water pump is engaged. This
is accomplished by using the "OK to PUMP" circuit to trigger the PTO system.
Wiring the PTO switch circuit in parallel with the "OK to Pump" light is one way to ensure
that the PTO and compressor cannot be activated unless the fire pump is engaged.
From
“OK to Pump”
“OK to
Pump”
Light
PTO
Switch
Ground
To PTO