In this case, an L-C-L network can be used to provide high-frequency isolations among the modules. For example, for
Atlas U3, C1 is between the Atlas HV and Pwr_Gnd. It serves as the bank capacitor for Atlas operation when
necessary. L1 is between Atlas HV and power supply positive output. L2 is between Atlas Pwr_Gnd and power supply
ground return. The current rating of L1 and L2 has to fit the Atlas operation current. L1 and L2 will bring in high
impedance at high frequency to attenuate the ground current. A separated L-C-L network is used for Atlas U4 for
optimum performance.