RestoreOperatingMode
2E
h
Syntax
RestoreOperatingMode
Motor Types
Arguments
None
Packet
Structure
Description
RestoreOperatingMode
is used to command Atlas to return to its static operating mode. It should
be used when the active operating mode has changed due to actions taken from safety events or
other programmed events. Calling
RestoreOperatingMode
will re-enable all loops that were
disabled as a result of events.
Restrictions
Before using
RestoreOperatingMode
to return to the static operating mode, the event status bits
should all be cleared. If a bit in event status that caused a change in operating mode is not cleared, this
command will return an error. If using Magellan, the
RestoreOperatingMode
command should be
sent to a Magellan axis, rather than to an Atlas axis. Otherwise Magellan will immediately disable Atlas
again.
see
GetActiveOperatingMode
Set/GetEventAction
DC Brush
Brushless DC
Microstepping
RestoreOperatingMode
checksum
2E
h
15
8 7
0