![PMD Atlas Compact Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/pmd/atlas-compact/atlas-compact_complete-technical-reference_1569420123.webp)
Atlas® Digital Amplifier Complete Technical Reference
123
6
Reset (cont.)
39
h
Description
(cont.)
Notes
Restrictions
The typical time before the device is ready for communication after a reset is 250ms for Atlas
products.
Not all of the listed variables are available on all products. See the product user’s guide.
see
Default Value
Low Power Medium Power High Power Buffered
Overvoltage Limit
38,207 (52 V)
38,207 (52 V)
44,085 (60 V)
N
Undervoltage Limit
7348 (10 V)
7348 (10 V)
7348 (10 V)
N
Overtemperature Limit 19,200 (75
°
C)
19,200 (75
°
C)
19,200 (75
°
C))
N
Temperature Hysteresis 1280 (5
°
C)
1280 (5
°
C)
1280
(5
°
C)
N
Continuous Current Limit
BLDC
9172 (2.12 A)
9264 (7.07 A)
9264 (14.14 A)
N
DC Brush
6486 (1.5 A)
9172 (7.00 A)
9172 (14.00 A)
N
Step
9172 (2.12 A)
8338 (6.37 A)
8338 (12.73 A)
N
Energy Limit
BLDC
502 (3.0 A
2
s)
498 (31.9 A
2
s)
498 (127.5 A
2
s)
N
DC Brush
617 (3.6 A
2
s)
503 (32.2 A
2
s)
503 (128.7 A
2
s)
N
Step
502 (3.0 A
2
s)
542 (34.7 A
2
s)
542 (138.9 A
2
s)
N