26
(L) and neutral (N) wires. Make
sure that the L and N conductors
are not exchanged within the
building's electrical system, e.g. in
an electrical socket or in an
electrical socket junction box!
All peripherals (such like: pumps,
RE-marked relays and connected
recipients) may be connected only
by qualified persons in accordance
with applicable regulations. Safety
precautions
to
prevent
electrocution should be observed.
Controller should be equipped with
a set of pins connected to the 230
VAC mains.
Connect protective wire of power supply
cable to ground strip linked with metal boiler
housing. Connect coupling to the terminal of
the controller indicated with a sign
and
to earthing terminals of devices connected to
the controller. Mistake! Not possible to find
an information cradle.
Tips of connection cables, especially mains
voltage cables should be secured from
splitting by e. g. insulated clamp sleeves in
accordance with the picture below: a) –
properly secured, b) – improperly secured.
Insulated clamp sleeve, 6mm
lenght.