25
placing the module on the rail, lift up the
catch. Now, place the module on the rail and
press the catch to bring it to the original
position. Make sure the device is firmly
fastened and cannot be easily removed from
the rail without use of tools.
For safety reasons, assure the safe distance
between live parts of working module
terminals and conductive (metallic) elements
of housing (min. 10 mm) is kept.
Protect connecting wires from tearing,
loosening and tensioning or built them in in
such a way that no load is exerted on them.
Space
requirements
for
working
module
mounting.
Methods of module installation: a) – in modular
housing with access to front surface, b) – in the
cover without access to front surface, 1- working
module, 2 – DIN TS35 rail, 3 – catch.
12.5
IP protection rate
Enclosure of the controller’s executive
module provides various IP protection rates,
depending on the method of installation.
After enclosing in accordance with this
drawing, the device has protection rate IP20
from the front side of the executive module
enclosure (specified on the rating plate).
From the side of the terminals, the casing
has protection rate IP00, thus the terminals
of the executive module must unconditionally
be enclosed, in order to prevent access to
this part of the casing.
If it is necessary to access the part with the
terminals, disconnect the mains supply,
make sure that there is no voltage on
terminals and leads, and remove the
executive module enclosure.
12.6
Connecting electrical system
Controller is designed to be fed with 230
VAC, 50 Hz voltage. The electrical system
should be:
three core, with protective wire PE,
in accordance with applicable regulations,
equipped with a residual current
protection device (RCD) with inrush
current IΔn≤30 mA, protecting against
the effects of electric shock and limiting
damage to the controller, including
protection against fire.
After deactivating the controller,
there still can be a dangerous
voltage on the connections. Before
starting assembly works it is
obligatory
to
disconnect
the
electrical power and make sure
that there is no danger electrical
power on claps and wires.
The connection wires should not have contact
with surfaces of temperature exceeding the
nominal temperature of their operation.
Terminals number 1-21 are intended only for
connecting devices with mains supply 230
VAC. Terminals 22-49 are intended for
cooperation with low voltage devices (below
12 V).
Connecting mains supply 230 VAC
to
terminals
22-49
and
to
transmission
connectors
will
damage the controller and creates
risk of an electric shock!
Connect power supply wires to terminals
indicated with an arrow
.
For safety reasons, the controller
must be absolutely connected to
the 230 VAC power grid, with the
sequence of connecting the phase
Содержание ecoMAX860P3-KL
Страница 6: ......
Страница 7: ...USER SETTINGS ecoMAX860P3 KL...
Страница 18: ...18...
Страница 19: ...19 INSTALLATION AND SERVICE SETTINGS ecoMAX860P3 KL...
Страница 44: ...44...
Страница 45: ...45...
Страница 46: ...46...
Страница 47: ...47...
Страница 48: ...48 ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www pum pl...