SAFETY INSTRUCTIONS
Before installing or using a Plug-In Solar kit, please read all instructions and cautionary markings in
this document and on the Micro-Inverters and Solar Panels.
The installation of a Plug-In Solar kit shall be carried out by a competent person with sufficient skills
and training to apply safe methods of work, in compliance with G83/2 Engineering
Recommendations.
The installation of a Plug-In Solar kit will be carried out to no lower a standard than that required in
the Manufacturer’s installation instructions, as provided here.
No parameter relating to the electrical connection and subject to type verification certification will
be modified unless previously agreed in writing between the DNO (Distribution Network Operator)
and the Customer.
All electrical installations shall be performed in accordance with local electrical codes.
All appropriate health and safety regulations must be observed and required safety precautions
taken.
Be aware that installation of this equipment includes the risk of electric shock.
Be aware that the body of the Micro-Inverter is the heat sink and can reach a temperature of 80°C.
To reduce risk of burns, do not touch the body of the Micro-Inverter.
DO NOT disconnect the PV module from the Micro-Inverter without first disconnecting the AC
power.
!
In no circumstances, connect a DC input when an AC connector is unplugged.
DO NOT attempt to repair a Micro-Inverter. If it fails, contact APS Customer Support to obtain an
RMA number and start the replacement process. Damaging or opening a Micro-Inverter will void
the warranty.
CAUTION!
!
The external protective earthing conductor is connected to the micro-inverter
protective earthing terminal via an AC connector.
!
When connecting; connect the AC connectors
first to ensure the micro-inverter earthing then undertake the DC connections. When
disconnecting; disconnect the AC by opening the branch circuit breaker. Whilst maintaining the
protective earthing conductor in the branch circuit breaker, connect to the micro-inverter, then
disconnect the DC inputs.
!
You MUST follow the IET Wiring Regulations at all times and consult a professional
electrician if you are in any doubt.