9
7077-801F • 08/20
B. User Dial Control
The appliance has one dial control located on the side of the
unit used for daily operation. There are four primary settings
on this dial.
•
Off:
- When the dial indicator is in the off position the unit
will go into a shut down and remain off until the dial is
turned to one of the other three settings. The LED will
flash green once per second when in the off position.
• MIN:
- When the dial indicator is directed to the MIN setting
(small flame on the label) the unit will burn on low
until the hopper runs out of pellets or the dial control
is turned to a different setting. When in this setting
the LED will be amber in color and continuously on.
When burning in this mode, the unit should be turned
off at least once daily for cleaning. If lower quality
fuels are used, additional daily shut downs may be
required for cleaning.
• MAX:
- Similar to the MIN mode, the unit will run continuously
at the high burn rate until the unit has run out of fuel
or the dial is turned to a different setting. To operate
in this mode, turn the dial clockwise until it stops. The
dial indicator will point to the large flame. When in this
setting the LED will be amber in color and continuously
on. Follow the daily cleaning recommendations when
operating in this mode. If lower quality fuels are used,
additional daily shut downs may be required for
cleaning.
• AUTO:
- To burn in the Automatic mode, turn the dial control
clockwise to the desired comfort level. When
operating in the automatic mode, the unit changes
the burn setting based on the difference between
the room temperature and the desired set point. In
other words, the unit will burn on High if the difference
between the desired and room temperature is greater
than 8 degrees Fahrenheit. As the room heats up and
the gap closes, the unit will automatically reduce the
burn rate. When the room temperature is close to the
set point the light will stop flashing stay solid green.
At this time the stove will be burning on the lowest
burn rate. When the desired temperature is achieved
the unit will shut down. As the room cools, the unit
will restart automatically. When burning in this mode
the LED will be blinking green. The number of green
flashes corresponds to the current burn rate.
C. Filling the Hopper
Slowly open the hopper lid by lifting the handle. The medium
and large units have a locking latch that will engage when
the hopper lid is fully opened. The hopper lid for the cabinet
will open past ninety degrees and stay open automatically.
Fill the hopper with fuel.
FOR USE WITH ONLY WOOD
PELLET FUEL.
Slowly close the hopper lid. See figure
below for releasing the latch.
0
-1
-2
-3
-
4
+1
+2
+3
+
4
AU
TO
MA
TIC
/ AU
TOMÁTICO / AUT
OM
ATIQ
UE
OFF
MA
X
MIN
ON
AUTO
AL
AR
M
Empuje parte inferior de
enganche hacia el interior
para liberar
NOTE:
The unit will not feed with the hopper lid open. If
left open, the fire will go out.