background image

 

 

 

 

 

 

User's Manual 

 

 

 

 

 

FSD-804PS 

 

8-Port 10/100Mbps with  

4-Port PoE  

Web Smart Ethernet Switch 

 

 

 

 

 

 

   
 
 
 
 
 

 

- 1 - 

Содержание FSD-804PS

Страница 1: ...User s Manual FSD 804PS 8 Port 10 100Mbps with 4 Port PoE Web Smart Ethernet Switch 1...

Страница 2: ...we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These...

Страница 3: ...Management 16 3 3 2 PLANET Smart Discovery Utility 18 4 WEB CONFIGURATION 20 4 1 MANIN MENU 20 4 2 WEB PANEL 21 4 3 SYSTEM 21 4 3 1 System Information 22 4 3 2 IP Configuration 22 4 3 3 Password Sett...

Страница 4: ...THERNET OVERVIEW 62 7 THE POE PROVISION PROCESS 64 7 1 LINE DETECTION 64 7 2 CLASSIFICATION 64 7 3 START UP 65 7 4 OPERATION 65 7 5 POWER DISCONNECTION SCENARIOS 65 8 TROUBLESHOOTING 66 APPENDIX A NET...

Страница 5: ...s access points IP based surveillance camera or IP phones in any places easily efficiently and cost effective The front panel of FSD 804PS provides LEDs for easy recognition of the switch operation st...

Страница 6: ...ed 10 100Mbps auto negotiation Flow control for full duplex operation and back pressure for half duplex operation Integrates address look up engine support 1K absolute MAC addresses Automatic address...

Страница 7: ...65 watts 221 BTU Dimension W x D x H 217 x 135 x 43 mm Weight 1 0 kg Power over Ethernet PoE Standard IEEE 802 3af Power over Ethernet PSE PoE Power Supply Type End Span PoE Power Output Per Port 48V...

Страница 8: ...ve humidity non condensing Storage Humidity 5 to 90 relative humidity non condensing Standard Compliance IEEE 802 3 IEEE 802 3u IEEE 802 3x IEEE 802 3af IEEE 802 1p IEEE 802 1Q Ethernet Fast Ethernet...

Страница 9: ...PoE switch device ie FSD 804PS term of switch can be any third switches 2 1 Front Panel The Front Panel of the FSD 804PS PoE Web Smart Ethernet Switch consists of 8x Auto Sensing 10 100Mbps Ethernet R...

Страница 10: ...inks to indicate that the Switch is actively sending or receiving data over that port 1 Press the RESET button once The Switch will reboot automatically 2 Press the RESET button for 5 seconds The Swit...

Страница 11: ...Mbps after the negotiation with the connected device Cabling Each 10 100Base TX ports use RJ 45 sockets similar to phone jacks for connection of unshielded twisted pair cable UTP The IEEE 802 3u Fast...

Страница 12: ...iscussed in Chapter 1 Section 4 in Specification Step4 Connect your Switch to network devices A Connect one end of a standard network cable to the 10 100 RJ 45 ports on the Back of the Switch B Connec...

Страница 13: ...to attach brackets to one side of the Switch Figure 2 5 Attaching the brackets to the Switch You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect s...

Страница 14: ...ne port of the FSD 804PS using Category 3 4 5 UTP STP cabling 4 Connect another switch or PC to the other port of FSD 804PS by following the same process as described in Step 3 Figure 2 7 End node or...

Страница 15: ...oice over IP phones Enterprise can install POE VoIP Phone ATA and other Ethernet non Ethernet end devices to the central where UPS is installed for un interrupt power system and power control system 6...

Страница 16: ...r platform compatible with TCP IP protocols Above PC installed with WEB Browser and JAVA runtime environment Plug in It is recommended to use Internet Explore 6 0 or above to access Web Smart Switch 3...

Страница 17: ...owing login screen appears please enter the default username admin and password admin or the password you have changed via console to login the main screen of PoE Switch The login screen in Figure 3 2...

Страница 18: ...rt Discovery Utility 1 Deposit the Planet Smart Discovery Utility in administrator PC 2 Run this utility and the following screen appears Figure 3 3 PLANET Smart Discovery Utility Screen If there are...

Страница 19: ...above are shown as below Update Device use current setting on one single device Update Multi use current setting on choose multi devices Update All use current setting on whole devices in the list Th...

Страница 20: ...enu screen The four items and it description shown as below System Provide System information and configuration of Switch Explained in section 4 3 Port Management Setup per port mode Rate Limit Port d...

Страница 21: ...MAC address Software Version Hardware Version IP address Subnet Mask and Gateway Explained in section 4 3 1 IP Configuration Allow to change the IP subnet address of Switch Explained in section 4 3 2...

Страница 22: ...MAC address Software Version The current software version running on the Switch Hardware Version The current hardware version of the Switch IP Address The current IP Address of the Switch Subnet Mask...

Страница 23: ...enable the DHCP client function to work The factory default is Disable IP Address The IP address of the Switch The factory default value is 192 168 0 100 Subnet Mask The IP subnet mask of the Switch...

Страница 24: ...h is 16 characters Confirm This confirms the new password The password entered into this field must be exactly the same as the password entered in the Password field 4 3 4 Firmware Upgrade This sectio...

Страница 25: ...Upgrade button after the image is loaded Or the system won t apply the new firmware Users have to repeat the firmware upgrade processes again Do not use Firefox or Windows Vista platform for FSD 804P...

Страница 26: ...the storage block on this converter Restore To restore the previous backup configuration from the storage block Factory To reset the Injector Hub back to the factory default mode Figure 4 10 Configur...

Страница 27: ...sconnected for a while Reload the Web browser to re login the system Figure 4 13 Configuration restore screen Factory Reset The Factory Reset button can reset the PoE Switch back to the factory defaul...

Страница 28: ...address of host to receive SNMP trap from the device Trap event Can choose which event can send the SNMP trap The trap events include Cold Star Login Fail Password changed IP Changed PoE Alert PoE SN...

Страница 29: ...creen appears in Figure 4 17 Please press OK button to take effect and the PoE Switch will reboot and ask you to re login web interface with correct username admin and password the screen in Figure 4...

Страница 30: ...en in Figure 4 20 appears and table 4 2 de scriptions the Port Setup objects of PoE Switch Figure 4 20 Port Setup Web Page screen The page includes the following configurable data Object Description P...

Страница 31: ...econd kbps Default No Limit Egress Shaping No Limit 128K 256K 512K 1M 2M 4M 8M Description Allow to set value for port Description This column accepts characters 0 9 A Z a z _ and Maximum 8 characters...

Страница 32: ...4PS Flow Control Display the flow control Disable or Enable state of each port on FSD 804PS Table 4 3 Descriptions of the Port Status screen Objects 4 4 3 Port Security The Layer 2 MAC address learnin...

Страница 33: ...ed port By which locks the port using the classic lock mechanism The port is immediately locked without permission of address learning 1 The Device will reboot after enable Port Security 2 After reboo...

Страница 34: ...N are implemented on the Switch 802 1Q VLAN require tagging which enables them to span the entire network assuming all switches on the network are IEEE 802 1Q compliant VLAN allow a network to be segm...

Страница 35: ...bytes 4 bytes 2 bytes 46 1517 bytes 4 bytes The Ether Type and VLAN ID are inserted after the MAC source address but before the original Ether Type Length or Logical Link Control Because the packet is...

Страница 36: ...tag or not If the transmitting port is connected to a tag unaware device the packet should be untagged If the transmitting port is connected to a tag aware device the packet should be tagged Default...

Страница 37: ...f the other ports The screen in Figure 3 6 appears The Switch supports Port based and 802 1Q Tagged based in Web management page In the default configuration VLAN support is Disable Figure 4 23 VLAN G...

Страница 38: ...gned to one or more VLAN groups Figure 4 24 VLAN Group Port Based VLAN screen While Port Based VLAN mode is selected the displayed page includes the following configurable data Object Description VLAN...

Страница 39: ...wn to be independent of the other ports The By setting the VLAN Type with 802 1Q IEEE 802 1Q tag based VLAN is enabled VLAN classification is the first step before VLAN table lookup The PoE Switch wil...

Страница 40: ...up to 16 active VLAN groups VID Specify the VLAN Identifier for the 802 1Q VLAN The available range of the VID is 1 to 4094 802 1Q mode only Member Port Select the physical interface for which you wa...

Страница 41: ...e used by other 802 1Q compliant devices on the network to make packet forwarding decisions Untagging Ports with untagging enabled will strip the 802 1Q tag from all packets that flow into those ports...

Страница 42: ...selected port it tells the switch whether to keep or remove the tag from a frame on egress Untag outgoing frames without VLAN Tagged Tagged outgoing frames with VLAN Tagged 802 1Q mod only PVID Allow...

Страница 43: ...Group 3 3 Port 4 Port 5 Port 6 Table 4 4 VLAN and Port Configuration The scenario described as follow Untagged packet entering VALN 2 1 While PC 1 transmit an untagged packet enters Port 1 the switch...

Страница 44: ...While the packet leaves Port 6 it will keep as a tagged packet with VLAN Tag 3 At this example VLAN Group 1 just set as default VLAN but only focus on VLAN 2 and VLAN 3 traffic flow Setup steps 1 Crea...

Страница 45: ...e ports would become overlap setting About the overlapped VLAN configuration see next VLAN configure sample 3 Assign PVID for each port Port 1 Port 2 and Port 3 PVID 2 Port 4 Port 5 and Port 6 PVID 3...

Страница 46: ...access with the same server The screen in Figure 4 25 appear This section will show you how to configure the port for the server that could be accessed by both VLAN 2 and VLAN 3 Figure 4 30 A Server...

Страница 47: ...ssigning 4 Setup Port 8 with PVID 1 at VLAN per Port Configuration page The screen in Figure 4 28 appears Figure 4 33 Setup Port 8 with PVID 1 That is although the VLAN 2 members Port 1 to Port 3 and...

Страница 48: ...ps 1 Port Setting 1 1 Assign VLAN 2 for the second VLAN group with Port 1 and Port 8 1 2 Repeat the same steps for Port 2 to Port 7 i e 2 8 3 8 7 8 After the above steps Port 1 to Port 7 is being sepa...

Страница 49: ...edia applications such as video conferencing or voice over IP by mini mizing delay and jitter Improve performance for specific types of traffic and preserve performance as the amount of traffic grows...

Страница 50: ...bits 1 bits 12 bits TPID Tag Protocol Identifier TCI Tag Control Information 2 bytes 2 bytes Preamble Destination Address Source Ad dress VLAN TAG Ethernet Type Data FCS 6 bytes 6 bytes 4 bytes 2 byte...

Страница 51: ...below Highest Lowest 4 1 Highest Lowest 8 1 The PoE Switch had define the VLAN tagged packets with User Priority value 4 7 are treated as high priority packets and the other User Priority values 0 3...

Страница 52: ...d dress VLAN TAG Optional Ethernet Type 0800 Data FCS 6 bytes 6 bytes 4 bytes 2 bytes 2 bytes 46 1517 bytes 4 bytes Figure 4 38 IPv4 frame format The Quality of Service page provides fields for defini...

Страница 53: ...own as below Highest Lowest 4 1 Highest Lowest 8 1 DSCP are defined in RFC2597 for classifying traffic into different service classes The PoE Switch extracts the code point value of the DS field from...

Страница 54: ...as the Figure 4 40 shows Figure 4 40 QoS Port Based Priority Configuration screen The page includes the following fields Object Description QoS Mode The draw menu allows customization of QoS mode for...

Страница 55: ...tion and drops the incoming broadcast or multicast packets Disable Disable broadcast storm protection function and forwards the in coming broadcast or multicast packets to all ports The factory defaul...

Страница 56: ...udes the following fields Object Description IEEE 802 3x flow control Allow Enable or Disable flow control for selected port Enable 802 3x flow control is enabled on Full Duplex mode Disable No flow c...

Страница 57: ...econds which is the factory default 30 sec Enable Fast aging time a learned source address entry will be cleared within 30 seconds if it is not updated by the address learning process Disable Disable...

Страница 58: ...mplemented The PSU input power consumption is monitored by measuring voltage and current The input power consumption is equal to the system s aggregated power consumption The power management concept...

Страница 59: ...ion W It shows the PoE device current watt Power Limit It can limit the port PoE supply watts Per port maximum value must less 15 4 total ports values must less than the Power Reservation value Once p...

Страница 60: ...ual of FSD 804PS 4 10 Logout Press this function the Web interface will go back to login screen The screens in Figure 4 44 and Figure 4 45 appear Figure 4 44 Logout dialogues screen Figure 4 45 Login...

Страница 61: ...oming frame in an internal buffer do the complete error checking before transmission Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Ether...

Страница 62: ...n legacy switch and the powered device Mid Span is tap the unused wire pairs 4 5 and 7 8 to carry power the other four is for data transmit End Span End Span device is direct connecting with power dev...

Страница 63: ...company moves into new offices next month The company staff has been clamoring for a wireless access point in the picnic area behind the building so they can work on their laptops through lunch but th...

Страница 64: ...ates 14 5 20 5 12 5 25 0 Startup Where the powered device will startup 42 38 Normal operation Supply power to device 36 57 25 0 60 0 7 1 Line Detection Before power is applied safety dictates that it...

Страница 65: ...ollowing disconnection of a PD from an active port When a PD is disconnected there is a danger that it will be replaced by a non PoE ready device while power is still on Imagine disconnecting a powere...

Страница 66: ...full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting Why the Switch doesn t connect to the network Sol...

Страница 67: ...er 3 Receive Data Power 4 5 6 Receive Data Power 7 8 A 2 Switch s RJ 45 Pin Assignments Port 5 to Port 8 Contact MDI MDI X 1 1 TX 3 2 2 TX 6 3 3 RX 1 6 6 RX 2 4 5 7 8 Not used Not used A 3 RJ 45 cable...

Страница 68: ...White Brown 8 Brown Straight Cable SIDE 1 SIDE2 SIDE 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 G...

Страница 69: ...ET POE 151S 12 CAM IR338 NT 5 1W LED Off 5 PLANET POE 151S 12 CAM IR338 NT 13 5W 14 3W LED On 6 PLANET VIP 155PT 3W 7 PLANET VIP 154PT 4 9W 5 6W 8 PLANET VIP 550PT 4 4 5W 9 PLANET WAP 4060PE 4 3W Stan...

Отзывы: