58-352
configured
Collector port is 6343
the sFlow global destination port is the defaulted 6343
Sampler priority is 2
The priority of sFlow when receiving packets from the hardware is
2.
Sflow DataSource: type 2, index
194(Ethernet1/1)
One sample proxy data source of the sFlow is the interface e1/1
and its type is 2 (Ethernet), the interface index is 194.
Collector address is 192.168.1.200
The analyzer address of the sampling address of the E1/1
interface is 192.168.1.200
Collector port is 6343
Default value of the port on E1/1 interface sampling proxy is
6343.
Counter interval is 20
The statistic sampling interval on e1/1 interface is 20 seconds
Sample rate is input 10000, output 0
The ingress traffic rate of e1/1 interface sampling proxy is 10000
and no egress traffic sampling will be performed
Sample packet max len is 1400
The length of the sFlow group data sent by the e1/1 interface
should not exceed 1400 bytes.
Sample header max len is 50
The length of the packet data head copied in the data sampling of
the e1/1 interface sampling proxy is 50
Sample version is 4
The datagram version of the sFlow group sent by the E1/1
interface sampling proxy is 4.