8-188
Usage Guide:
After configuring the multiplier, the aging time is defined as the product of the multiplier and the interval of sending
messages, and its maximum value is 65535 seconds.
Example:
Set the value of the aging time multiplier as 6.
Switch(config)#lldp msgTxHold 6
8.8 lldp neighbors max-num
Command:
lldp neighbors max-num <
value
>
no lldp neighbors max-num
Function:
Set the maximum number of entries can be stored in Remote MIB.
Parameters:
<
value
>
is the configured number of entries, ranging from 5 to 500.
Default:
The maximum number of entries can be stored in Remote MIB is 100.
Command Mode:
Port Configuration Mode.
Usage Guide:
The maximum number of entries can be stored in Remote MIB.
Example:
Set the Remote as 200 on port ethernet 1/5 of the switch.
Switch(config)#in ethernet 1/5
Switch(Config-If-Ethernet1/5)# lldp neighbors max-num 200