11-217
11.15 ethernet-oam errored-frame-seconds window
Command:
ethernet-oam errored-frame-seconds window <
seconds
>
no ethernet-oam errored-frame-seconds window
Function:
Configure the detection period of errored frame seconds event, no command restores the default value.
Parameters:
<
seconds
>
is the time for counting the specified frame number, its range from 50 to 450, unit is 200ms.
Command Mode:
Port mode
Default:
300.
Usage Guide:
Detect errored frame seconds of the port after the time of specific detection period. If the number of errored frame
seconds is larger than or equal to the threshold, corresponding event is induced and the device notified the peer
through OAMPDU.
Example:
Configure the detection period of errored frame seconds event on port 1/4 to be 120s.
Switch(Config-If-Ethernet1/4)#ethernet-oam errored-frame-seconds window 600
11.16 ethernet-oam errored-symbol-period threshold high
Command:
ethernet-oam errored-symbol-period threshold high {<
high-symbols
> | none}
no ethernet-oam errored-symbol-period threshold high
Function:
Configure the high threshold of errored symbol event, no command restores the default value.