SNMP Monitoring
The current settings and status of UltraLux units can be remotely monitored using
SNMP (Simple Network Management Protocol), if the SNMP option is enabled
through the web browser settings. The MIB (Management Information Base) used for
all Planar display products is available by electronic distribution in the file
PLANAR-
DISPLAY-MIB.txt
. The table below shows the objects that can be monitored – all
Planar SNMP objects are read-only, and no traps are used. The default read-only
community string for all Planar SNMP objects is “public”. Once the PLANAR-DISPLAY-
MIB is loaded in your SNMP manager, you can walk all the available objects from the
top-level object PlanarSystems(1.3.6.1.4.1.19125) or its sub-object
PlanarDisplayProduct(1).
Most object values are integer type, except where noted. Generally, for integer types,
the value -1 is returned if there is any internal system or communication error, and
normal return values are zero or positive integers.
Object Name
Description
Value
plnrModel
Model name (string)
UltraLux
plnrInputSelect
User-selected input source
1 = HDMI, 2 = DisplayPort, 3 = VGA
plnrInputStatus
Input source status
0 = Source Absent, 1 = Source Present
plnrDisplayBacklight
Backlight on/off state
1 = On, 0 = Off
plnrDisplayBrightness
User-selected brightness value
0-100
plnrDisplayContrast
User-selected contrast value
0-100
plnrDisplaySharpness
User-selected sharpness value
0-8
plnrDisplayColorSpace
User-selected color space
0 = full color
2 = sRGB
plnrDisplayColorTemp
User-selected color temperature
2 = 4200K
3 = 5000K
4 = 6500K
5 = 7500K
6 = 9300K
7 = user
plnrDisplayGainRed
User-selected red gain value
Note:
Gain values apply only
when color temperature
setting is 7 or user.
0-100
plnrDisplayGainGreen
User-selected green gain value
0-100
plnrDisplayGainBlue
User-selected blue gain value
0-100
plnrAudioVolume
User-selected volume setting
0-100
plnrAudioMute
User-selected audio mute
1 = On, 0 = Off
plnrPower1
Power supply #1 status
1 = OK, 0 = Failed
plnrPower2
Power supply #2 status
1 = OK, 0 = Failed
Содержание UltraLux Series
Страница 1: ...Planar UltraLux Series...
Страница 58: ...On Screen Display Menus 58 Planar UltraLux Series Installation Guide Image Menu...
Страница 62: ...On Screen Display Menus 62 Planar UltraLux Series Installation Guide System Menu...
Страница 66: ...66 Planar UltraLux Series Installation Guide UltraLux Dimensions 70 Display Dimensions Front and Side Views...
Страница 67: ...70 Display Dimensions Rear View Planar UltraLux Series Installation Guide 67 70 Display Dimensions Rear View...
Страница 75: ...80 Display Dimensions Rear View Planar UltraLux Series Installation Guide 75 80 Display Dimensions Rear View...