78
OPTION menu
Item
Description
SERVICE
(continued)
COMMUNICATION
(continued)
SERIAL SETTINGS
Select the serial communication condition for the
CONTROL
port.
BAUD RATE
4800bps
9600bps
19200bps
38400bps
PARITY
NONE
ODD
EVEN
• The BAUD RATE is
fi
xed to 19200bps and PARITY
is
fi
xed NONE when the COMMUNICATION TYPE
is set to OFF
(
76, 77
)
.
TRANSMISSION METHOD
Select the transmission method for communication by
the NETWORK BRIDGE from the
CONTROL
port.
HALF-DUPLEX
FULL-DUPLEX
HALF-DUPLEX: This method lets the projector
make two way communication, but only one
direction, either transmitting or receiving data, is
allowed at a time.
FULL-DUPLEX: This method lets the projector
make two way communication, transmitting and
receiving data at the same time.
• HALF-DUPLEX is selected as the default setting.
• If you select HALF-DUPLEX, check the setting of
the item RESPONSE LIMIT TIME
(
79
)
.