6/12
6.6 Limits of use
- Use the device following the instructions, complying with its operation limits and the
standards in force.
- The devices have specific application limits (min. and max. ambient temperature,
mechanical endurance, IP protection degree, etc.) These limitations are met by the
device only if considered individually and not as combined with each other.
- The manufacturer’s liability is to be excluded in the following cases:
1) Use not conforming to the intended purpose;
2) Failure to adhere to these instructions or regulations in force;
3) Fitting operations not carried out by qualified and authorized personnel;
4) Omission of functional tests.
- For the cases listed below, before proceeding with the installation contact our techni-
cal assistance service (see paragraph SUPPORT):
a) In nuclear power stations, trains, airplanes, cars, incinerators, medical devices or
any application where the safety of two or more persons depend on the correct
operation of the device;
b) Applications not contemplated in this instruction manual.
7 MARKINGS
The outside of the device is provided with external marking positioned in a visible
place. Marking includes:
- Producer trademark
- Product code
- Batch number and date of manufacture. Example: A19 FD1-123456. The batch's first
letter refers to the month of manufacture (A=January, B=February, etc.). The second
and third letters refer to the year of manufacture (19 = 2019, 20 = 2020, etc…).
8 TECHNICAL DATA
8.1 Housing
FP, FR, FX series:
housing made of glass fibre reinforced technopolymer,
self-extinguishing, shock-proof and with double insulation
FD, FL, FM, FZ series: Metal housing, baked powder coating
Conduit entries:
FD, FP, FR, FM series: one threaded conduit entry M20x1.5 (standard)
FL series:
three threaded conduit entries M20x1.5 (standard)
FX series:
two knock-out threaded conduit entries M20x1.5 (standard)
FZ series:
two threaded conduit entries M20x1.5 (standard)
Protection degree:
IP67 acc. to EN 60529 with cable gland of equal
or higher protection degree
8.2 General data
SIL (SIL CL):
up to SIL 3 acc. to EN 62061
Performance Level (PL):
Up to PL e acc. to EN ISO 13849-1
Safety parameters:
B10d:
2,000,000 for NC contacts
Mission time:
20 years
Ambient temperature:
-25°C … +80°C
Storage temperature:
-40°C … +80°C
Max. actuation frequency:
1 cycle / 6 s
Mechanical endurance:
1 million operating cycles
Max. actuation speed:
0.5 m/s
Min. actuation speed:
1 mm/s
Actuating force:
initial 63 N, final 83 N
8.3 Electrical data
8.3.1 Versions without connector:
Thermal current (I
th
):
10 A
Rated insulation voltage (U
i
):
500 Vac 600 Vdc
Rated impulse withstand voltage (U
imp
): 6 kV
Conditional short circuit current:
1000 A acc. to EN 60947-5-1
Protection against short circuits:
type aM fuse 10 A 500 V
Pollution degree:
3
Utilization categories:
Alternating current: AC15 (50÷60 hz)
U
e
(V)
250
400
500
I
e
(A)
6
4
1
Direct current: DC13
U
e
(V)
24
125
250
I
e
(A)
3
0.55
0.3
8.3.2 Versions with M12 connector, 4 or 5-pole:
Thermal current (I
th
):
4 A
Rated insulation voltage (U
i
):
250 Vac 300 Vdc
Protection against short circuits:
type gG fuse 4 A 500 V
Pollution degree:
3
Utilization categories:
Alternating current: AC15 (50÷60 hz)
U
e
(V)
24
120
250
I
e
(A)
4
4
4
Direct current: DC13
U
e
(V)
24
125
250
I
e
(A)
3
0.55
0.3
8.3.3 Versions with M12 connector, 8-pole:
Thermal current (I
th
):
2 A
Rated insulation voltage (U
i
):
30 Vac 36 Vdc
Protection against short circuits:
type gG fuse 2 A 500 V
Pollution degree:
3
Utilization categories:
Alternating current: AC15 (50÷60 hz)
U
e
(V)
24
I
e
(A)
2
Direct current: DC13
U
e
(V)
24
I
e
(A)
2
8.4 Compliance with standards
EN 60947-5-1, EN 60947-1, EN 60204-1, EN ISO 14119, EN ISO 12100, EN 60529,
UL 508, CSA 22.2 N. 14.
8.5 Compliance with directives
Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, RohS Directive
2011/65/EU.
9 SPECIAL VERSIONS ON REQUEST
Special versions of the device are available on request.
The special versions may differ substantially from the indications in this instruction
sheet.
The installer must ensure that he has received written information from the support
service regarding installation and use of the special version requested.
10 DISPOSAL
At the end of service life product must be disposed of properly, according to the rules
in force in the country in which the disposal takes place.
11 SUPPORT
The device can be used for safeguarding people’s physical safety, therefore in case of
any doubt concerning installation or operation methods, always contact our technical
support service:
Pizzato Elettrica Srl
Via Torino, 1 - 36063 Marostica (VI) - ITALY
Tel39.0424.470.930
E-mail [email protected]
www.pizzato.com
Our support service provides assistance in Italian and English.
DISCLAIMER:
Subject to modifications without prior notice and errors excepted. The data given in this sheet are
accurately checked and refer to typical mass production values. The device descriptions and its
applications, the fields of application, the external control details, as well as information on installa-
tion and operation, are provided to the best of our knowledge. This does not in any way mean that
the characteristics described may entail legal liabilities extending beyond the “General Terms of
Sale”, as stated in the Pizzato Elettrica general catalogue. Customers/users are not absolved from
the obligation to read and understand our information and recommendations and pertinent technical
standards, before using the products for their own purposes. Taking into account the great variety of
applications and possible connections of the device, the examples and diagrams given in the present
manual are to be considered as merely descriptive; the user is deemed responsible for checking that
the specific application of the device complies with current standards. This document is a translation
of the original instructions. In case of discrepancy between the present sheet and the original copy, the
Italian version shall prevail. The present manual may not be reproduced, in whole or in part, without
the prior written permission by Pizzato Elettrica.
© 2019 Copyright Pizzato Elettrica. All rights reserved.