70
-
Enter on location VD+8 the duration of accelaration ramp (expressed
as time units; if duration of acceleration ramp must be 1 second and
function GENSET is recalled by an interrupt of 1 ms, enter 1000)
-
Enter on location VD+10 the duration of deceleration ramp.
-
Write “1” on location VD to start the function which will automatically
start to write on location VD+2 the generated setpoint. Location VD will
also be updated with current state of function, while location VD+12will
be updated with instant speed of setpoint, expressed with 3 decimals.
This value may be used to generate action “F” for function POSPID.
At end of motion, when location VD+2 will reach value of final setpoint,
the function will automatically enter standby mode, indicated by value
“0” on location VD. This means that function GENSET can be always
active, even when motion is not required.