FULL PACK MC BOX etl
3
SAFETY INSTRUCTIONS
WARNING
Electrical supply -
preliminary checks
for the installation
Completely avoid contact between the electrical supply and the liquid
to be pumped.
Inspection and
maintenance
operations
Before any inspection or maintenance, cut off the POWER SUPPLY
FIRE AND
EXPLOSION
When flammable
liquids are present
in the work area,
flammable vapours
may be present
and may cause fire
or explosion during
station use.
To prevent fire and explosion risks:
Use the station only in ventilated areas
Keep the work area free of scraps, including scraps and solvent or petrol
tanks.
Do not plug or unplug or operate the switch in the presence of flammable
vapours.
All devices in the work area must be grounded.
Interrupt immediately any action if there are sparks or shocks. Do not use
the station until you have identified and resolved the problem.
Keep a fire-extinguisher in good working order close to the working area.
ELECTRICAL
SHOCK
Electrocution or
death
F
This station must be grounded. Improper installation or use of the station
may result in danger of electric shock.
Switch off and unplug the power cord after use.
Connect only to grounded sockets.
Use only grounded cables in accordance with the applicable regulations.
Unsuitable extension leads may be dangerous.
Make sure that the plug and socket of the extension cords are intact.
Unsuitable extension leads may be dangerous.
In outdoor use, use only extensions suitable for the specific use, according
to the regulations in force.
The plug and socket must be connected far from water.
Do not expose to rain. Install in a sheltered location.
Never touch the plug or the socket with wet hands.
Do not turn the dispensing system on if the supply connection cable,
WARNING parts of the unit, e.g. the suction/delivery pipe, the nozzle
or the safety devices are damaged. Replace the damaged pipe immediately
before use.
Before each use, check that the mains connection cable and the plug are
not damaged. If damaged, have the cable and plug replaced by qualified
personnel.
The plug and socket must be connected far from water.
Outdoors, use only authorised extension leads for which this use is
envisaged with an adequate wire diameter in accordance with the
regulations in force.
As a general rule of electrical safety it is always recommended to power the
device by protecting the line with:
- circuit breaker/disconnector with a current rating suitable for the power
line
- 30 mA residual current device
The electrical connection must have a ground fault current interrupter
(GFCI).
Installation operations are carried out with the box open and the electrical
contacts accessible. All these operations must be carried out with the unit
isolated from the mains in order to avoid hazards of electrocution!