13
/124
13
/48
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
translated from Italian
FULL PACK MC BOX etl
9 OPERATION
The controller is powered by 100/240 V ac, it drives a motor that can absorb a maximum current of
15 A. It has a 4-character backlit display, iButton reader, blue led for Bluetooth connection and red
led for warning/alarm:
• NOT FOR RESALE • NICHT EICHFÄHIG • PARA UTILISACION EXCLUSIVA DEL USUARIO •
INTERDIT POUR TOUTES TRANSACTIONS COMMERCIALES OU FISCALES • APPARECCHIO
NON IDONEO ALLA MISURAZIONE DI PRODOTTI PER LA VENDITA AL PUBBLICO • NE È
VIETATO L’USO IN RAPPORTO A TERZI • CIRC. MIN. N°67 DEL 25/07/1996 •
MADE in ITALY
RED LED:
when on, a display coding
is shown which indicates a
series of warnings or alarms.
See error coding table.
DISPLAY
Backlighting on:
the driver or manager has been authenticated via smartphone or the driv-
er has been authenticated via iButton.
The display shows:
•
the version of the installed firmware,
•
the value of the dispensing,
•
the time,
•
warning or alarm code when the red LED is on,
•
the boot status for the firmware update,
•
the percentage of firmware transferred.
BLUE LED:
when lit, it
indicates that
a device is
connected in
Bluetooth
IBUTTON reader
NOTE
Red LED on - It switches on due to several factors, each time the LED lights
up the display shows a code indicated by a letter A and by an incremental
number. Whenever the led is on, it is not possible to dispense.
Below are the possible coded errors, with their respective resolution methods:
Coding Description
Explanation/Solution
C1
WARNING_MASTER_PUMP_
GROUPA_LEVEL1_CONTACT
Contact 1 associated with pump A of the main controller is
active: red LED flashing.
C2
WARNING_MASTER_PUMP_
GROUPA_LEVEL2_CONTACT
Contact 2 associated with pump A of the main controller
is active: red LED flashing.
C3
WARNING_MASTER_PUMP_
GROUPA_THR1
The tank associated with pump A of the main controller
has reached the level 1 threshold: red LED flashing.
C4
WARNING_MASTER_PUMP_
GROUPA_THR2
The tank associated with pump A of the main controller
has reached the level 2 threshold: red LED flashing.
C9
WARNING_SLAVE_PUMP_
GROUPA_LEVEL1_CONTACT
Contact 1 associated with pump A of the secondary con-
troller is active: red LED flashing.
C10
WARNING_SLAVE_PUMP_
GROUPA_LEVEL2_CONTACT
Contact 2 associated with pump A of the secondary con-
troller is active: red LED flashing.
C11
WARNING_SLAVE_PUMP_
GROUPA_THR1
The tank associated with pump A of the main controller
has reached the level 1 threshold: red LED flashing.
C12
WARNING_SLAVE_PUMP_
GROUPA_THR2
The tank associated with pump A of the secondary con-
troller has reached the level 2 threshold: red LED flashing.