13
Duo Mode Sequencing
Duo Mode Sequencing
The Touch Controller can quickly create 1 or 2 simultaneous sequences using the Channel Animator
section. The Left and Right Zones can be used to create 2 independent sequences. If the Left Zone
sequence is active, the LEFT OUTPUT SECTION is updated, if the Right Zone sequence is active, the
RIGHT OUTPUT SECTION is updated.
The ALL GATE OUTPUT (19) is triggered by an active step in the Left Zone or and active step in the
Right Zone. The ALL Y-AXIS OUTPUT (22) represents the Y-Axis value of the last Left or Right active
sequence step. The ALL CV A OUTPUT (20) outputs a SUM of the active Left VOLTAGE PRESET
KNOB A and the active Right VOLTAGE PRESET KNOB A. The ALL CV B OUTPUT (21) outputs a
SUM of the active Left VOLTAGE PRESET KNOB B and active Right VOLTAGE PRESET KNOB B.
Summing the Left and Right VOLTAGE PRESET KNOBs creates interesting potential for transposition
and larger CV output voltages.
Clocking a Sequence
The sequences are clocked using the STEP INPUT JACK (10). Sending a trigger or gate into the STEP
INPUT JACK (10) will advance the sequences 1 step.
Duo Sequence Clock Divider
A clock divider can be used to divide the incoming clock signal. The Left Zone Sequence and the Right
Zone Sequence can be divided independently. The clock divider for each zone can be set to ÷1, ÷2, ÷3,
÷4, or ÷8. Set the clock division by pressing and holding the RESET/REST BUTTON then pressing the
corresponding TOUCH PLATE in the Left or Right Zone.
The selected clock divisions are not saved when the Touch Controller is powered off. The default clock
division is ÷1.