12
Mono Mode Sequencing Section
(2 of 2)
Programming a Sequence
In Mono Mode, the Sequencer treats all 10 Touch Plates as a single monophonic touch interface. A
sequence is recorded by pressing and holding the MONO BUTTON (5). While the MONO BUTTON (5)
remains pressed, up to 64 steps can be added to the sequence by tapping the Touch Plates. The Y-
Axis is also recorded into the sequence during programming.
While the MONO BUTTON (5) remains pressed, a Touch Plate can be pressed multiple times to repeat
a step.
While the MONO BUTTON (5) remains pressed, the RESET/REST BUTTON (6) can be pressed to add
a rest step in the sequence.
The sequence begins cycling through the programmed steps as soon as the first step is programmed
and a trigger or gate signal triggers the STEP INPUT JACK (10). To prevent the sequence from cycling
during programming, remove the clock from the STEP INPUT JACK (10) until programming is finished.
Clearing a Sequence
Press and release the MONO BUTTON (5) without touching a TOUCH PLATE to clear the sequence.
Switching from Mono to Duo clears the sequence.
Powering off the Touch Controller will clear the sequence.
Attention!
While a sequence is running, touching the TOUCH PLATES will not trigger the channel. Instead,
touching a TOUCH PLATE will re-record the Y-Axis. This allows the Y-Axis recorded into the sequence
to be modified without changing the selected channel sequence.
If the Touch Plates are not responding to touch, Press and release the MONO BUTTON (5) to clear the
active sequence and enable the Touch Plates.