Section Two: OPERATION
PIT BOSS CONTROL
LCD SCREEN
Displays Grill Temperature, Smoke Settings
(P Setting), igniter and temperature status, and error
TEMPERATURE DIAL
Select the following: Smoke (low), High, or one of
8 temperatures.
“P” SET (recessed push button)
Select one of 7 temperature fine tunings. Allows for
Larger temperature control to fit your cooking style
HIGH - HIGH TEMPERATURE MODE
Grill operates at the Highest heat level. When Lid is
“OPEN” the grill will run at this speed
SMOKE - LOW TEMPERATURE MODE
Grill operates at the Lowest Temperature. This level
can be adjusted as well, using the “P” Set button.
NOTE: This setting does not produce high
volumes of visible smoke.
888
Displays momentarily when the grill is connected to
AC power.
OVERVIEW
LCD SCREEN READOUTS
ACTUAL TEMPERATURE
Grill temp. is displayed in 5 degree (°F) increments.
FLASHING ACTUAL TEMPERATURE
When grill temperature is below 150°F.
FLASHING DOTS
Indicates when the Igniter is “ON”.
“P” SETTINGS P0 - P7
When the Temperature Dial is in the Smoke mode,
“P 4” is the factory set default.
“ErH” FLASHING ERROR
Grill temperature has exceeded 615°F. .
“ErP” FLASHING ERROR
Temperature Dial was not in the OFF position when
the grill was connected to AC power. Also indicated a
Power Outage occurred while the grill was operating.
OFF
Starts the “Cool Down Cycle”. Turning off the Feed
System, while letting the fan operate to efficiently cool
down the grill for 2 minutes.
“ErR” FLASHING ERROR
Grill Probe malfunction or disconnected from board.
Page 20