2011 NEW PRODUCTS
Please be sure to read before handling the product. Please refer to "safety instructions", "common safety instructions for products listed in this manual", "common safety instructions for flow controller" from page 24 through 35.
6
S
pecification
Item
Full-scale flow
005
010
020
050
100
200
500
101
201
Flow rate
range
(*1)
005 500ml/min
●
010 1l/min
●
020 2l/min
●
050 5l/min
●
100 10l/min
●
200 20l/min
●
500 50l/min
●
101 100l/min
●
201 200l/min
●
Port size
4 ø4mm Quick-fitting
●
●
●
●
●
●
6 ø6mm Quick-fitting
●
●
●
●
●
●
●
8 ø8mm Quick-fitting
●
●
●
10 ø10mm Quick-fitting
●
●
Built-in needle valve N
(*9)
●
●
●
●
●
●
●
●
●
Flow rate display
(*1) (*2)
Display method
4 4 digits, 2 color LCD
Display
range
F
0~500
m
l
/min
0~1000
m
l
/min
0~2.00
l
/min
0~5.00
l
/min
0~10.00
l
/min
0~20.0
l
/min
0~50.0
l
/min
0~100.0
l
/min
0~200
l
/min
R -500~500
m
l
/min
-1000~1000
m
l
/min
-2.00~2.00
l
/min
-5.00~5.00
l
/min
-10.00~10.00
l
/min
-20.0~20.0
l
/min
-50.0~50.0
l
/min
-100.0~100.0
l
/min
-200~200
l
/min
Minimum unit setting
1m
l
/min
0.01
l
/min
0.1
l
/min
1
l
/min
Accumulation
(*3)
Max flow rate
9999999m
l
99999.99
l
999999.9
l
9999999
l
Mini. unit setting
1m
l
0.01
l
0.1
l
1
l
Accumulated pulse output rate
5m
l
10m
l
0.02
l
0.05
l
0.1
l
0.2
l
0.5
l
1
l
2
l
Working
condition
Fluid medium
(*4) Clean air (JIS B8392-1.1.1 to 5.6.2), Compressed air (JIS B8392-1.1.1 to 1.6.2),
and nitrogen gas
Max working pressure
0.7MPa
Min working pressure
-0.09MPa
Withstand pressure
1MPa
Ambient Temp. & humidity
0 to 50ºC, max. 90%RH
Working fluid temp.
0 to 50ºC (no dew condensation)
Accuracy
Assured accuracy range
3 ~ 100%F.S.
Linearity (display/analog output)
Max
±
3%F.S. (Air vent for 2ndary side
、
25ºC)
Pressure characteristics
Max
±
5%F.S. (-0.09 to 0.7MPa, where air vent for 2ndary side is reference)
Temp. characteristics
Max
±
0.2%F.S./ºC (15 to 35ºC, where 25ºC is reference)
Repeatability
Max.
±
1%F.S.
Response time
(*5)
Max.50ms
Output
Switch output
N 2 points output (NPN open collector output: max. 50mA, voltage drop: max. 2.4V)
P 2 points output (PNP open collector output: max. 50mA, voltage drop: max. 2.4V)
Analog output
V
1 voltage output 1 to 5V (connected load impedance: min. 50kΩ)
A
Current output 4 to 20mA (connected impedance: 0 to 300Ω)
Power supply voltage (*6)
V
DC12 ~ 24V (10.8 ~ 26.4V)
A
DC24V (21.6 ~ 26.4V)
Current consumption
(*7)
Max.50mA
Lead wire
ø3.7 AWG26 equiv. x 5 core cable (connector joint), Insulator O.D. ø1.0mm
Functions
Flow rate display, flow rate - peak hold, switch output, analog output, and other
Installation Installing orientation
Horizontal or vertical
Straight pipe introduction
Not required
Protective structure
IEC standard: IP40
Protective circuit
(*8) Power supply and switch output reverse connection protections, and switch output
load short-circuit protection
EMC directive
Conformity