Auto-reference function
When CH2 is set to auto-reference, the threshold of switch output can be read by external input or button operations. The threshold is changed
automatically when the threshold of switch changes, such as when workpiece changes. The input value is the flow rate when the external input
is turned ON.
The switch setting of CH2 is disabled during auto-reference operation.
No. of input Operation pattern
Description
Timing chart
LCD display
1 point
ON above input
value
The switch turns ON when on or
higher than the read value.
(Threshold: input value)
Flow rate
ON
OFF
Input value
<Sub display>
<Main display>
OFF above input
value
The switch goes OFF when on or
higher than the read value.
(Threshold: input value)
Flow rate
ON
OFF
Input value
2 points
ON above the
mean value of 2
points
The switch goes ON when on or
higher than the mean value of two
read points.
(Threshold:("input 1"+ "input2")/2)
Flow rate
ON
OFF
Input value
Input value
OFF above the
mean value of 2
points
The switch goes OFF when on or
higher than the mean value of two
read points.
(Threshold:("input 1"+ "input2")/2)
Flow rate
ON
OFF
Input value
Input value
ON between 2
points
The switch goes ON between two
read points.
(Threshold 1: input value 1)
(Threshold 2: input value 2)
Flow rate
ON
OFF
Input value
Input value
OFF between 2
points
The switch goes OFF between two
read points.
(Threshold 1: input value 1)
(Threshold 2: input value 2)
Flow rate
ON
OFF
Input value
Input value