Flow Sensor
>
>
>
http://www.pisco.co.jp
Please be sure to read before handling the product. Please refer to "safety instructions", "common safety instructions for products listed in this manual", "common safety instructions for flow controller" from page 24 through 35.
31
Common Safety Instructions for Products Listed in This Manual
■
Warning/cautions of installation & adjustment
1. Piping
Cautions
■
Installation and plumbing must be done prior to wiring.
■
It must be piped, while matching the flow direction and direction specified on the body.
■
Please flash the pipe by air blow to remove foreign substances and swarf, etc., in inside of pipe before piping. If many foreign materials
and swarf, etc. entrain into the inside, the rectifier and the sensor tip could be damaged.
■
If a quick-fitting is used, the tube must be inserted certainly. Please pulls the tube to check that it will not come out. Cut the tube at the
right angle with the dedicating cutter.
2. Installation
Cautions
■
The flow display uses liquid crystal. It may be hard to see by an angle.
■
This product can be installed with any orientation; vertical, horizontal, right or left.
Horizontal (through hole)
Bracket installation (use dedicated bracket)
Vertical (female thread on the bottom)
Model no. of bracket
:FUS20-B1
Fixing screw
Fixing screw
Fixing screw
* Tightening torque of fixing screw is 0.5N.m.
* Tightening torque of fixing screw is 0.5N.m.
Panel mount installation
Fixing screw
*1. Tightening torque of fixing screw is 0.06N.m.
*2. Please make plumbing before installation.
*3. If plumbing is made after installation, the part may be
broken by excessive force.
*4. If panel mounting is selected, please avoid vibrations are
not affecting to the sensor.
3. Wiring
Danger
■
Power supply voltage and outputs must be used with the specified voltage.
Applying more than specified voltage may cause malfunction, damage of sensor, electric shock or fire.
Please do not apply load more than the rated output. Damage of the output or fire may be caused.
Warnings
■
Line color must be checked when wiring. Please check the wiring color with handling precaution, since improper wire connection may
result in damage, failure or malfunction of the sensor.
■
Insulation of wiring must be checked.
Please eliminate contact, ground fault and terminal insulation defective with other circuits, or overcurrent will be admitted into the sensor,
and damage is caused.
■
For the electrical power supply, please use rated stabilized DC power supply insulated from AC power supply. If power supply is not
insulated, electric shock may be created. If power supply is not stabilized, the peak magnitude may exceed the rated value, causing
damage of this product, or reducing the accuracy.
■
Please make sure to put connector cover on after connecting connector.
■
Please do not stress a cable drawing position directly or connector.