Some functions and settings are completed when the normal flow is displayed, and some after entering setting mode. The setting mode is
divided into standard setting mode and detailed setting mode based on the frequency of use.
■
Explanation of function
●
Normal operation
Item
Description
Default setting
Real-time flow display
Real-time flow rate is displayed.
−
Accumulated flow display
It can be changed to accumulated flow display.
The switch output function includes turning the switch ON and OFF when the
specified accumulated value is exceeded, and an accumulated pulse function
that outputs a pulse after a set count value. It will be reset if power is turned
off and can be reset with button operation or external input.
Real-time flow display
Peak hold function
Maximum and minimum flow rates within a set interval are displayed.
Peak hold OFF
Key lock function
Key operations are disabled to prevent incorrect operation.
Key lock invalid
Error display function.
The status of errors is displayed when trouble or error occurs.
−
●
Standard setting mode
Item
Description
Default setting
Switch output function
Having 2 points switch output, 7 operation patterns and operation stop can
be set.
Both CH1 and CH2 are
set to switch OFF
Forced output function
Switch output is forcibly turned on to check line connections and default
operation of the input device.
−
Zero adjust function
Zero point deviation is corrected. (Range : 0
±
10%F.S.)
Adjusted value: 0